SOLARDRIVE
PLUS
PROGRAMMING
GUIDE
48
/
107
P009
Acceleration Time at Start 1
Range
0
32700
0
327.00 s se
P014
=0
0.01 s
0
3270.0 s se
P014
=1
0.1 s
0
32700 s se
P014
=2
1 s
0
327000 s se
P014
=3
10 s
Default
Depending on size
Level
BASIC
Address
609
Function
Ramp for motor start.
Determines the time the reference takes to go from 0 rpm to the max. preset speed (considering the
max. value between absolute values for max. speed and min. speed of the motor).
P010
Deceleration Time at Stop 1
Range
0
32700
0
327.00 s se
P014
=0
0.01 s
0
3270.0 s se
P014
=1
0.1 s
0
32700 s se
P014
=2
1 s
0
327000 s se
P014
=3
10 s
Default
Depending on size
Level
BASIC
Address
610
Function
Ramp for motor stop.
Determines the time the reference takes to go from the max. preset speed (considering the max.
value between absolute values for max. speed and min. speed set for the motor) to zero rpm.
P012
Acceleration Time at Start 2
Range
0
32700
0
327.00 s se
P014
=0
0.01 s
0
3270.0 s se
P014
=1
0.1 s
0
32700 s se
P014
=2
1 s
0
327000 s se
P014
=3
10 s
Default
Depending on size
Level
ADVANCED
Address
612
Function
Same as ramp 1 (see
P009
).
NOTE
Values for ramp 2 can be applied to the reference provided that multiramp digital inputs are set up
and that ramp 2 is selected (for more details, contact Enertronica Santerno).