SOLARDRIVE
PLUS
PROGRAMMING
GUIDE
28
/
107
2.4.
Start Up Menu
2.4.1.
Overview
For easier startup of the Solardrive Plus, you can activate the Start-Up Menu. The Start-Up Menu is a wizard
allowing programming the main parameters.
The Start-UP Menu is displayed by pressing the START-UP key from the keypad.
The following is the root page of the Start-Up menu:
[ I D P ] S O L A R D R I V E
S T A R T - U P M E N U
P r e s s E N T E R
t o s t a r t
Press
ENTER
to enter the wizard.
Before entering the control parameters, you are asked to choose a dialogue language:
P 2 6 3 L a n g u a g e
@ @ @ @ @ @ @ @ @ @ @ @ @ @ @
Once the dialogue language has been selected, the Start-up menu appears. The available parameters are
listed below:
Parameter
Description
C015
Rated mains voltage
C016
Rated motor rpm
C017
Rated motor power
C018
Rated motor current
C019
Rated motor voltage
C029
Max. motor speed
C800
Minimum Pump Speed
P009
Acceleration time to start 1
P010
Deceleration Time to stop 1
P018
Start Acceleration Time
P019
End Deceleration Time
P020
Speed Threshold for Initial and Final Ramps
C265
Motor thermal protection
C267