PROGRAMMING
GUIDE
SOLARDRIVE
PLUS
11
/
107
Cxxx
Parameters (Read Only when the drive is running and the motor is operating; R/W when the drive is in
stand-by or in Run, but the motor is stopped).
Cxxx
Description
Range
Drive representation
(integer)
Display on the display/keypad and the RemoteDrive
(may be a decimal figure)
plus unit of measure
Default
Factory-setting of the parameter
(as represented for the drive)
Factory-setting of the parameter
(as displayed)
plus unit of measure
Level
User level (BASIC / ADVANCED / ENGINEERING)
Address
Modbus address which the parameter can be read from/written to
(integer)
Control
This optional field is displayed when a parameter is not active for all types of motor controls (IFD / VTC /
FOC)
Function
Parameter description
Rxxx
Parameters (Read Only when the drive is running and the motor is operating; R/W when the drive is in
stand-by or in Run, but the motor is stopped).
Rxxx
Description
Range
Drive representation
(integer)
Display on the display/keypad and the
RemoteDrive
(may be a decimal figure)
plus unit of measure
Default
Factory-setting of the parameter
(as represented for the drive)
Factory-setting of the parameter
(as displayed)
plus unit of measure
Level
User level (BASIC / ADVANCED / ENGINEERING)
Address
Modbus address which the parameter can be read from/written to
(integer)
Control
This optional field is displayed when a parameter is not active for all types of motor controls (IFD /
VTC / FOC)
Function
Parameter description
NOTE
Unlike Cxxx parameters, Rxxx parameters become active only after the drive has been switched
off and switched on again, or after resetting its control board by pressing the RESET button for
more than 5 seconds