Technical data
Micropilot M FMR 240 with PROFIBUS PA
98
E Hauser
10.1.5
Operating conditions: Process
Dielectric constant
•
in a stilling well/Wave Guide antenna:
ε
r
≥
1,4
•
in free space:
ε
r
≥
1,9
10.1.6
Mechanical construction
Weight
•
F12/T12 housing: approx 4 kg + weight of flange
•
F23 housing: approx 7.4 kg + weight of flange
10.1.7
Certificates and approvals
CE approval
The measuring system meets the legal requirements of the EC-guidelines.
Hauser confirms the instrument passing the required tests by attaching the
CE-mark.
RF approvals
R&TTE, FCC
Overspill protection
german WHG, see ZE 244F/00/de.
SIL 2, see SD 150F/00/en "Functional Safety Manual".
External standards and
guidelines
EN 60529
Protection class of housing (IP-code)
EN 61010
Safety regulations for electrical devices for measurement, control, regulation and
laboratory use.
EN 61326
Emissions (equipment class B), compatibility (appendix A - industrial area)
NAMUR
Standards committee for measurement and control in the chemical industry
Type of antenna / Seal / Temperature
1
1)
For Wave Guide antenna the max. temperature at the process connection (thread/flange)
may be 200 °C (392 °F).
V
Standard, Viton, -20 °C...+150 °C (-4 °F...+302 °F)
E
Standard, GLT, -40 °C...+150 °C (-40 °F...+302 °F)
K
Standard, Kalrez, 0 °C...+150 °C (-32 °F...+302 °F)
Pressure
vacuum ...40 bar (...580 psi)
Media
max. viscosity of 500 cst for Wave Guide antenna
Antenna cone
PTFE
Wetted parts
PTFE, seal and 1.4404/1.4435/316 L resp. Alloy C22