Mounting
Micropilot M FMR 240 with PROFIBUS PA
22
E Hauser
Examples for the construction of stilling wells
L00-FMR240xx-17-00-00-en-011
100 %
0 %
100 %
0 %
Micropilot M
FMR 240
Micropilot M
FMR 240
threaded connection
R 1½”),
G 1½" (FMR 244)
or 1½ NPT
1½” BSPT (
marker
inside of
holes deburred
< 1/10 Ø pipe
stilling well
with slots
full bore
ball valve
hole <1/10 pipe diameter,
single sided or drilled through
inside of
holes deburred
marker
e.g. welding neck flange
DIN 2633
< 1/10 Ø pipe
gap
1 m
m
0.04
”
£ £
gap
1 m
m
0.04
”
£ £
150
…
500 mm
6
”…
20
”
150
…
500 mm
6
”…
20
”
Diameter of o
of ball valve must always
be equivalent to pipe diameter.
Avoid edges and constrictions.
pening