Memocheck Sim CYP03D
Operation
Hauser
33
8.2.9
Extended functions: Oxygen (amp.)
Path: Menu/Advanc. function
Function
Configuration options
(factory settings in bold)
Calibration value
Slope
0.1 pA/hPa to 5.0 nA/hPa
313.5 pA/hPa
Zero point
-3.2 nA to 3.2 nA
0.0 pA
Temp. offset
-10.0 to 10.0 ˚C
0.0 ˚C
Temp. gradient
-3.0 to 3.0
1.0
Temp. coeff. 1
20.00 E-03 to 40.00 E-03
30.79 E-03
Temp. coeff. 2
100.0 E-06 to 500.0 E-06
447.6 E-06
Temp. coeff. 3
500.0 E-09 to 5.000 E-06
4.224 E-06
Temp. coeff. 4
1.000 E-09 to 70.00 E-09
66.75 E-09
Содержание Memocheck Sim CYP03D