LT5
Installation
Hauser
53
5.11 Guide wire installation
Installation procedure
• Do not bend the guide wires.
• Two guide wires should be arranged in parallel to one other and perpendicular to
the tank floor.
• Check the two packings (for top anchor and tank flange) on which slip washers are
usedbefore setting the guide wires.
• Check the strength of the guide wire and the anchor hook at the tank bottom, as
they are difficult to repair once the tank is filled with liquid.
1. Open the cover of the top anchor located at the top of the tank.
2. Pass the guide wire through the guide ring at the tank bottom and secure it tightly to
the anchor hook using a nut and a bolt.
3. Cut and bend the tip of the guide wire so that it does not get caught on the float.
The tip of the guide wire is connected to (b) so that it is smaller than the
dimension of the anchor hook (a).
Coil the guide wire 1 to 2 times from the inside of the anchor hook, and then
pass it through a hole and coil it 1 to 2 times on the outside.Adjust the number of
coils as necessary.
A
5
6
3
4
2
1
a
7
8
1
9
b
A0041206
38
Guide wire installation 1
A
Anchor hook
1
Guide wires
2
Guide ring
3
Float
4
Measuring tape
5
Universal joint
6
Welding point
7
Washer
8
Anchor hook
9
Bolt
4. Extend the guide wire at the tank top again and secure it in place.
5. Bend the end of the guide wire against the main shaft and cut it off, leaving approx.
100 mm.
6. Tighten the end nuts [1] and [2].