Installation
LT5
66
Hauser
5.13.2 Filling seal pot with liquid sealant for an installed gauge
Liquid sealant filling procedure
NOTICE
If used liquid sealant is mixed with liquid from the tank, it may become a hazardous
substance.
‣
Do not allow used liquid sealant to come in contact with unprotected hands.
Pay careful attention to the materials of containers, etc., into which liquid sealant is
poured.
1. Place a container that is 2 l (L) or larger beneath the drain.
2. After confirming the safety of the vicinity around the tank, remove the seal pot drain
plug.
3. Drain the liquid sealant from the seal pot.
4. Open the 90 ° sheave elbow cover.
1
2
3
A
4
5
A0041230
54
Draining liquid sealant
A
To the LT5 side
1
sheave elbow
2
90 ° sheave elbow
3
90 ° sheave elbow cover
3
Drain plug
5
Container that is 2 l or larger
5. Close the drain plug and inject liquid sealant until it reaches the middle of the scale
on the side of the seal pot.
6. Close the sheave elbow cover.
This completes the liquid sealant filling process.