5.12 Measuring tape and measuring wire installation
• Never bend or damage the measuring tape.
• Ensure that the measuring tape does not become twisted inside the tank or while
the pipes are being laid out.
• Approximately half of the measuring tape is perforated with small holes at a 20-
mm intervals (1-inch intervals if using imperial units). Install the measuring tape so
that the perforated side is wound by the gauge.
• Check to make sure that the measuring tape and the measuring wire do not come
off the sheave elbow roller during the process, and inspect them after they have
been installed.
• If the measuring tape must be passed through the 135 ° sheave elbow, ensure safety
before installing the measuring tape, as the footing is extremely dangerous.
• Inspect the joint between the float and the measuring tape once they are connected,
as it cannot be fixed once the tank is filled with liquid.
Installation procedure
1. Extend the measuring tape while folding it back and forth in your hand
approximately every 1.5 m to ensure that the tape does not become twisted.
2. Open the sheave elbow cover and the gauge head cover.
3. Install the measuring tape so that it does not become twisted inside the guide pipe.
This completes the preparation for the measuring tape installation.
1.
1.
2.
1
2
3
1
5
0
0
0
(5
9
.1
)
A0041208
40
Measuring tape preparation. Unit of measurement mm (in)
1
Perforation
2
sheave elbow
3
Cover