Installation
LT5
62
Hauser
5.12.5 Internal parts adjustment
Tape guide adjustment procedure
1. Turn the tape drum inside the gauge head in the direction of the arrow in the
diagram below to make the measuring tape taut.
1
2
3
4
5
6
7
A0041215
48
Tape drum
1
Measuring tape
2
Sprocket
3
Tape drum
4
Tape-holding thread
5
Dust protector
6
Tape guide
7
Locking screw
2. Once taping is complete, set the tape guide so that both ends are approximately
2 mm (0.08 in) from the surface of the measuring tape as shown below.
The measuring tape may come off the sprocket pins due to sudden movement
caused by waves of the liquid. The tape guide prevents this.
3. If a dust protector is installed, loosen the installation threads (2 threads) and make
adjustments so that the measuring tape does not interfere with the dust-proof slit.
This completes the tape guide adjustment process.
2
1
3
2 (0.08)
4
2 (0.08)
5
A0041216
49
Tape guide adjustment. Unit of measurement mm (in)
1
Sprocket
2
Measuring tape
3
Installation screws
4
Measuring tape
5
Tape guide