102
Parameter setting
Weather Station Suntracer KNX sl
• Version: 14.07.2016 • Technical changes and errors excepted.
Interior temperature block
Below a certain interior temperature, the curtain can be prevented from opening.
Set whether an interior temperature block is to be used. The threshold value can also
be set by "changeable per object".
Then set the threshold value for the temperature block and the hysteresis for the event
that the value is not reached.
When specifying the threshold value
by object
the minimum and maximum values
that can be set and the increment for the change are also defined.
Define the value of the release object for the interior temperature block. Using the re-
lease object, the interior temperature block can be deactivated at short-notice.
Solar protection automation
If none of the blocks is active, then the position of the sun and the brightness are
checked and is, corresponding to the solar protection automation, shaded.
Set whether solar protection automation is to be used.
Define the value of the release object for solar protection automation. Using the re-
lease object, solar protection automation can be deactivated at short notice.
Use
• No
• Yes
• Changeable per object
Allow shading at internal temperature above
Threshold value (in 0.1°C increments)
(
if changeable:
until first call)
-32768 ... 32767; 200
Hysteresis (in 0.1°C)
-200 ... 300; 20
Minimum variable per object
Threshold value (in 0.1°C increments)
-32768 ... 32767; 100
Maximum variable per object
Threshold value (in 0.1°C increments)
-32768 ... 32767; 350
Increment for threshold value
change (in 0.1°C)
1 ... 20; 5
Evaluation of the interior temperature
blocking release object
1 = activated | 0 = deactivated
0 = activated | 1 = deactivated
value until first call
0 • 1
Use
No •
Yes
Evaluation of the solar automation release
object
1 = activated | 0 = deactivated
0 = activated | 1 = deactivated
value until first call
0 • 1