Block – blocking objects
The menu item only appears if a block with blocking object was configured for
"control". Here it is specified was happens for object value 1 and 0. Via the free blocking
object, a fire alarm scenario may be configured for example (create escape routes by
retracting the shading, smoke extraction via windows). This can prevent being locked
out on the patio (opened window contact of the patio door blocks the shutter in front
of the door).
Block – wind blocking
The menu item only appears if a wind blocking was configured for "control". The input
object "wind blocking" is linked with the output object of a wind sensor. The input can
be a 1bit object (smaller or larger than a threshold value), as well as a 16bit object
(measurement value).
Designation
[Block 1 ... 5]
Enter a designation here!
If blocking object has value =1
• no action
• stop
• move into position
• up-command • down-command
(shutter/blind)
• retract-command • extend-command
(awning)
• close-command • open-command
(window)
Position in % (only if by using a block, a
specific position is achieved)
0...100
Slat position in % (only if by using a block,
a specific shutter position is achieved)
0...100
If blocking object has value =0
For manual operation before and after
blocking
• no action
• move into last position
For automatic operation after blocking
follow automatic
Value of the object before the 1st
communication and bus voltage return
0...1
Designation
[Wind blocking]
Enter a designation here!
Type of input object
1 bit • 16 bit