Страница 1: ...EN Installation and Adjustment KNX RF S1R B2 compact Multifunctional Radio Actuator Item number 70715...

Страница 2: ......

Страница 3: ...uctions for assembly and operational start up 8 3 Addressing of the device at the bus 8 4 Disposal 9 5 Transfer protocol 10 5 1 List of all communication objects 10 6 Parameter setting 14 6 1 General...

Страница 4: ...eshooting of the device must only be carried out by a competent electrician Safety advice Safety advice for working on electrical connections components etc DANGER indicates an immediately hazardous s...

Страница 5: ...light fan 2 binary inputs Position feedback movement position also slat position for shutters Position storage movement position via 1 bit object storage and call up e g via buttons Parameters for ta...

Страница 6: ...The device is only to be used for the intended purpose described in this manual Any improper modification or failure to follow the operating instructions voids any and all warranty and guarantee claim...

Страница 7: ...the power supply is removed the connected drive switches off When the power is restored the consumer remains switched off until a new movement command is re ceived by the actuator WARNING Risk of inju...

Страница 8: ...drive or the loads to the OUT UA A1 A2 terminals The output is free of potential and supplied with voltage UA To connect the digital inputs fig 1 no 1 use the attached cable The cables for the inputs...

Страница 9: ...nical changes and errors excepted 2 4 1 Connection examples output Fig 2 Breakout cable for digital inputs Input 1 black white GND Input 2 yellow violet GND Drive 230 V AC Mains 230 V AC Two consumer...

Страница 10: ...ing this phase no information can be received or sent via the bus For KNX devices with safety functions e g wind or rain blocks it is important to set up periodical monitoring of the safety objects Th...

Страница 11: ...X RF S1R B2 compact Version 16 09 2020 Technical changes and errors excepted 4 Disposal After use the device must be disposed of or recycled in accordance with the legal reg ulations Do not dispose of...

Страница 12: ...1 Bit 107 Automatic movement position Input RWC 5 1 DPT_Scaling 1 Byte 108 Automatic blind position Input RWC 5 1 DPT_Scaling 1 Byte 109 Change from manual to automatic mode Input RWC 1 1 DPT_Switch 1...

Страница 13: ...status Output R CT 1 1 DPT_Switch 1 Bit 189 Block 2 Rain blocking object Input RWC 1 1 DPT_Switch 1 Bit 190 Block 3 Blocking object Input RWC 1 1 DPT_Switch 1 Bit 191 Block 3 Wind blocking object Inp...

Страница 14: ...ht function Input RWC 1 10 DPT_Start 1 Bit 217 Channel A1 Link Input RWC 1 2 DPT_Bool 1 Bit 218 Channel A1 Call up saving scenes Input RWC 18 1 DPT_SceneControl 1 Byte 220 Channel A2 Switch Input RWC...

Страница 15: ...260 Input 2 Extended Input Output RWCT 1 8 DPT_UpDown 1 Bit 261 Input 2 Short Output R CT 1 8 DPT_UpDown 1 Bit 262 Input 2 Switch Input Output RWCT 1 1 DPT_Switch 1 Bit 263 Input 2 Relative dimming In...

Страница 16: ...fications for the connected drive see Channel settings drives page 15 Control functions Movement range limit blocking type of automatic see Control drives page 17 Scenes Movement positions see Scenes...

Страница 17: ...between the end positions is the basis for moving into intermediate positions e g for movement range limits and scenes You can enter the runtime numerically in seconds or have the runtime determined...

Страница 18: ...rive should be adjusted according to the specifications of the motor manufacturer Reference movement With the regular movement to the two end positions the runtime and zero position are adjusted again...

Страница 19: ...t to open One of two drive mechanisms is prioritised and is parameterised as master and the other one as slave By means of zero position sensors both actuators know the own current status and the curr...

Страница 20: ...the window shall be opened The window knows the status of the awning not safe position and therefore submits a master command to the awning This is the signal for the awning to retract a little bit A...

Страница 21: ...red in their own menu items See Movement limits on Page 30 Use Block 1 high priority no yes with blocking object yes as wind blocking yes as rain blocking Use block 2 no yes with blocking object yes a...

Страница 22: ...ches in conference rooms Here it is also specified in which mode the channel is found when the voltage returns i e after a power failure The mode manual or automatic is send as a status object to the...

Страница 23: ...t wind blocking is linked with the output object of a wind sensor The input can be a 1bit object smaller or larger than a threshold value as well as a 16bit object measurement value Designation Block...

Страница 24: ...0 Slat position in only if by using a block a specific shutter position is achieved 0 100 Waiting period in secure position in min after blocking 0 255 5 Behaviour after waiting period For manual oper...

Страница 25: ...ose command open command window Position in only if by using a block a specific position is achieved 0 100 Slat position in only if by using a block a specific shutter position is achieved 0 100 Waiti...

Страница 26: ...actuator is linked to this group address A scene is called then the scene number is communicated to the actuator The movement position saved for this scene number in the actuator is then taken If the...

Страница 27: ...quently needed bus functions Thus the inputs can easily be configured as a switch drive control dimmer for sending values and for the scene calls Input as switch If a button with switch function is as...

Страница 28: ...shutter blinds awning or window control If the input to the drive control is used via the bus select the bus function shutter awning blinds or window and specify the button function and control mode S...

Страница 29: ...ocking object For active blocking there is no bus communication Input 8 bit encoder If the input is to be used as an 8bit encoder select the 8 bit encoder bus function and specify which value will be...

Страница 30: ...used as a brightness encoder e g threshold value of a sun sensor select brightness encoder and specify which value will be sent The input can be blocked using a blocking object For active blocking th...

Страница 31: ...tuating the button briefly a bit longer and long will trigger different responses of the drive The time intervals are set individually Short actuation shorter than Time 1 The drive is positioned step...

Страница 32: ...nctions page 30 Point in time 0 Actuate of button start of time 1 Release before time 1 expired step or stop if drive is moving Point in time 1 End of time 1 start of time 2 Moving command Release aft...

Страница 33: ...inutes The switch off delay effects that the ventilator will follow up if the button was operated again and the light is already off The staircase timer function makes sure for example that the light...

Страница 34: ...ings for the switch function channel if selected Use blocking functions Yes The output channel can be blocked by a block telegram What happens during the blocking for bus voltage return and after the...

Страница 35: ...ire alarm blocking When switching via communication object Channel A1 switch 210 the light is turned on or off normally When switching via object Channel A1 staircase light function start 215 the stai...