20
Parameter setting
Radio Actuator KNX RF S1R-B2 compact
• Version: 16.09.2020 • from application 1.0 •
Technical changes and errors excepted.
Short time restriction (for blinds):
If short time restriction is active, only short time movement commands are still
possible manually. If the function "Allow step commands only for blind adjustment" is
activated simultaneously, (see
, page 15) only the slats can
still be adjusted by hand but no longer the movement position of the shutter.
Restriction is active for object value 1.
Automatic reset:
With the manual operation the automatic of the drive is deactivated. Here it is set when
the automatic is reactivated.
Automatic blocking object:
With the automatic blocking object, the automatic can be deactivated for a short term
(e.g. if present or during speeches in conference rooms).
Here it is also specified in which mode the channel is found when the voltage returns,
i.e. after a power failure. The mode (manual or automatic) is send as a status object to
the bus.
Use short time limit
no • yes
Value of the object in front of 1.
communication and bus voltage
restoration
(if short time restriction is used)
0 • 1
Manual switches to automatic after
• expiry of a waiting period
• reception of an object
• reception of an object or
expiry of a waiting period
Waiting period in min
(if "Expiration of a waiting period" was
chosen)
1...255; 20
Switch to automatic for an object value
(if "Receipt of an object" was chosen)
0 • 1 • 0 or 1
Use automatic blocking object
no • yes
Automatic is blocked when
(if „yes“ was chosen)
0 • 1
Value of the blocking object after
resumption of power
(if „yes“ was chosen)
0 • 1
Operating mode after power returns
• Automatic
• Manual
Send status object
• 1 for automatic | 0 for manual
• 0 for automatic | 1 for manual
Send delay of the status output
Automatic or Manual in 0.1 sec
0...50