14
Parameter setting
Radio Actuator KNX RF S1R-B2 compact
• Version: 16.09.2020 • from application 1.0 •
Technical changes and errors excepted.
6.
Parameter setting
The default settings of the parameter are labelled by an underscore.
6.1. General settings
First set the general parameters for the bus communication (telegram rate,
transmission delay). Additionally, you can indicate if for the programming of scenes
all, or only the changed settings are applied to the bus.
6.2. Output
State here what is connected to the output channel.
Thereafter, the setting options will appear:
Settings for drives (shutter/blind/awning/window):
•
General specifications for the connected drive
(see
•
Control functions: Movement range limit, blocking, type of automatic
(see
•
Scenes: Movement positions (see
•
Button inputs: Configuration as actuator button, bust button or for zero position
sensor (see
Button inputs (drives) - Input as bus button
Transmission delay of threshold values
after power returns
5 s … 2 h
Send delay of switching and status
outputs after voltage returns
5 s … 2 h
For the use of scenes:
Application when programming
all parameters • only changed parameters
Label for objects
Enter a label here!
Operating mode
• do not use
• shutter
• blind
• awning
• window
• double switch function
Use input 1
no • yes
Use input 2
no • yes
Operating mode
Channel A controls
• shutter
• blind
• awning
• window
• double switch function