22
Installation and use MR16
4.1.4 Configuration of radio module MR16
Radio module MR16 operation is configured via DIP switch.
Figure 10
DIP switches
Function
Settings
A1 - A2
The switches arm wireless
devices acquisition and removal
steps
A1 A2
OFF OFF normal
operation
ON ON acquire
devices
OFF
ON
remove a device
ON
OFF
remove all devices
A3
Arm test
OFF = normal operation
ON
= test procedure armed
A4
Output relay operation mode for
inputs 1÷16
OFF = bistable
ON
= monostable
A5
Output relay typology for inputs
1÷16
OFF = normally closed (NC)
ON
= normally open (NA)
A6
Output relay typology SYS ST
OFF = normally closed (NC)
ON
= normally open (NA)
A7
Output relay typology ON/OFF
OFF = normally closed (NC)
ON
= normally open (NA)
A8
Output relay typology SAB / RF
SAB / BAT
OFF = normally closed (NC)
ON
= normally open (NA)
B1
Outputs 1÷8 subordinated to
radio module status
OFF = outputs subordinated
ON
= outputs not subordinated
B2
Enable jamming detection (radio
sabotage)
OFF = jamming control disarmed
ON
= jamming control armed
B3
Enable supervision
(radio sabotage)
OFF = supervision disarmed
ON
= supervision armed
B4
Enable radio module MR16
buzzer
OFF = buzzer enabled
ON
= buzzer disabled
B5
Enable PHYSICAL SABOTAGE
alarm
OFF = physical sabotage alarm enabled
ON
= physical sabotage alarm disabled
B6
Input S polarity
OFF = negative polarity
ON
= positive polarity
B7
Inhibit sirens tamper for 1 hour
OFF = siren rings at tamper opening
ON
= siren does not ring if tamper is opened within
one hour from DIP switch having switched over
B8
Silence sirens audio warnings
OFF = sirens do not acoustically warn about the
change of status of radio module MR16
ON
= sirens acoustically warn about the change of
status of radio module MR16
Command
Key
Содержание MR16
Страница 1: ...DS80IT19 004A LBT80725 MR16 Relay radio module Installation and user s Manual GB ...
Страница 42: ...42 Installation and use MR16 ...
Страница 43: ...Installation and use MR16 43 ...