4.1.2 Connection to power supply
Radio module MR16 takes power supply at 12 V— out of wired alarm control panel it is connected to.
Before making the connection, check for wired control panel to be able to provide current requested by
radio module, that is that overall absorption of control panel, devices, connected to control panel, and
radio module does not exceed the current which control panel power supply unit is able to supply.
Power supply cable must be connected at one side to pins + and – of radio module and at the other side
to wired alarm control panel 12 V— output. In connection, observe polarities!
Warning:
wired control panel side connection must be downstream of control panel power supply
unit and backup battery to assure radio module MR16 power supply also in lack of network power
supply (230 V).
Figure 6
Note:
should control panel not have a current reserve sufficient to supply radio module MR16 too, radio
module MR16 can also be supplied by an additional power supply unit provided with a backup battery,
such as AS02/6.