Installation and use MR16
23
4.1.5 Supervision function
Supervision is a regular check on the effectiveness of radio connection between radio module MR16 and
its peripheral units. Should the check be unsuccessful, relay RF SAB is armed. Supervision function is
enabled by DIP switch B3.
4.2 MICRO CONTACT DC500
Figure 11
4.2.1 Power supply
The device is provided with a pre-installed cell.
Remove the isolator pulling plastic tang on the rear side of the device.
After it was supplied, micro contact starts up an initialisation step which lasts about 2
minutes. During this step, its LED goes on blinking in colour red. When the LED goes off,
you can go on with acquisition step.
4.2.2 Acquiring detection devices
Warning:
acquiring the devices is a gradual operation; therefore, if you want that the devices are
paired to the outputs according to a certain order, you have to consider that acquiring sequence is
affected by the fact that the devices are acquired gradually.
Warning:
you cannot acquire devices if radio module MR16 is armed.
To make radio module MR16 acquire one or more micro contacts or IR detectors:
1. Set radio module MR16 to acquisition mode in following way:
a. Set DIP switches A1 and A2 to ON.
b. Press once control pushbutton on radio module MR16 (figure 11). Radio module sends out 3
beeps and LED
A
(green), indicating that you entered detection devices acquisition mode, and
status LEDs 1÷16 (red), of the inputs to which a number of devices are already paired, go on
steady.
c. Keep pressed for 3 seconds control pushbutton on radio module MR16. Radio module sends out 3
beeps and LED
A
blinks once to indicate that detection devices can be acquired.
2. Press the programming key of either micro contact or IR detector. The first of status LEDs 1÷16 that is free
goes on and radio module MR16 sends out 2 beeps for confirmation. If radio module MR16 sends out one
two-tone beep, it means that the limit was reached of devices that can be acquired and that no more
devices can be added.
3. Repeat from point 2 to acquire more detection devices, or reset both DIP switches A1 and A2 of radio
module MR16 to OFF to quit acquisition mode (radio module MR16 sends out one two-tone beep).
Radio module MR16 automatically quits acquisition mode if no operations are performed for 3
minutes.
LED and
programming / test key
Micro contact
Magnet