10
Installation and use MR16
2.2.3 Details on visual warning
Detection device open/closed status is immediately identified by its LED (there is one LED per input).
Physical sabotage warning (
)
1. Press
once control pushbutton at the front side on radio module MR16: 3 beeps are sent out and
LED
stops blinking and is lit steady.
2. Press control pushbutton and keep it pressed for 3 seconds:
•
radio module MR16 sends out 3 beeps,
•
LED
A
goes on steady,
•
one or more status LEDs 1÷16 go on to show which detection devices (micro contacts and IR
detectors) have had tamper open.
3. Press control pushbutton:
•
radio module MR16 sends out 1 beep,
•
LED
A
goes off and LED
B
goes on steady,
•
one or more status LEDs 1÷2 go on to show which actuation devices (sirens) have had tamper
open.
4. Press control pushbutton and keep it pressed for 3 seconds:
•
radio module MR16 sends out 3 beeps,
•
if the tampers of all wireless devices are closed, LED
goes off and alarm memory is erased;
otherwise, the LED resumes blinking.
5. Radio module MR16 returns to normal operation.
Warning:
physical sabotage memory is also erased at every radio module MR16 arming
operation, provided that cause generating the alarm is not still present.
Radio sabotage warning (
)
1. Press
twice control pushbutton at the front side on radio module MR16: 3 beeps are sent out and
LED
stops blinking and is lit steady.
2. Press control pushbutton and keep it pressed for 3 seconds:
•
radio module MR16 sends out 3 beeps,
•
LED
A
goes on steady,
•
one or more status LEDs 1÷16 go on to show which actuation devices (micro contacts and IR
detectors) have not replied to supervision.
3. Press control pushbutton:
•
radio module MR16 sends out 3 beeps,
•
LED
A
goes off and LED
B
goes on steady,
•
one or more status LEDs 1÷2 go on to show which actuation devices (sirens) have not replied
to supervision.
4. Press control pushbutton and keep it pressed for 3 seconds:
•
radio module MR16 sends out 3 beeps,
•
if all wireless devices replied to supervision, LED
goes off and alarm memory is erased;
otherwise, the LED resumes blinking.
5. Radio module MR16 returns to normal operation.
Notes:
•
if detail LEDs do not go on, radio sabotage is of jamming type;
•
if both missing reply to supervision and jamming were enabled and both sabotage types
occurred, radio module MR16 will only show details relating to missing supervision.
Warning:
radio sabotage memory is also erased at every radio module MR16 arming
operation, provided that cause generating the alarm is not still present.