28
Installation and use MR16
4.4.4 Configuration
The siren is configured via internal DIP switches.
Figure 19
At end of configuration, close back the device.
4.5 OUTDOOR SIREN HP500
4.5.1 Power supply
The device is provided with pre-installed batteries.
Loosen the screw at siren base and take off its covering.
Set power supply to ON to supply the siren.
Figure 20
4.5.2 Acquisition
For siren acquisition see paragraph
4.4.2 Acquiring actuation devices
.
1
ON = siren in acquisition mode
OFF = normal operation
2 reserved
3 -4
Setting the duration of siren ringing:
DIP 3
DIP 4
3 minutes
OFF
OFF
5 minutes
ON
OFF
10 minutes
OFF
ON
1 second for test
ON
ON
5 reserved
6
ON = reset (see paragraph
6.3.2 Reset sirens
)
OFF = normal operation
7 reserved