16.3 TORQUE-CURRENT ADJUSTMENT
16.3 TORQUE-CURRENT ADJUSTMENT
The following configuration allows to adjust, through a potentiometer, the current delivered by the output inverter
or the torque produced by the motor.
-
one potentiometer is on the analog input 1 (ANIN 1,
∅
2) for speed reference adjustment (frequency
-
one potentiometer is on the analog input 2 (ANIN 2,
∅
4) to adjust the delivered current (or torque).
To select between torque and current adjustment, set the signal to be feedback in the CURRENT LIMIT block:
the parameter FEED BACK SOURCE (TAG 366) allows to choose between CURRENT and LOAD, thus
obtaining both adjustments.