Aquastorm 200
4-42 Maintenance
Rear View of Aquastorm 200
TM
with Access Panels Removed
Rinse Tank
Wash Tank
Chemical Isolation Tank
3.2
RECIRCULATION FILTER
REPLACEMENT PROCEDURE
Tools and parts required to perform the
Recirculation Filter Replacement Procedure
•
Spanner Wrench
•
Wash and Rinse Tank Filter
p/n
2-8999-230-00-0
or
525485-01
•
Optional Chemical Isolation Tank Filter
p/n
2-8999-538-00-0
1
Press the wash, rinse, and optional
chemical isolation tank Drain Controls
via the membrane keypad to activate
the drain solenoids on the Aquastorm
200
™
.
2
Once the tanks have drained completely,
press the
Power Off Control to disable
system power
Wash Tank Basket Being Removed
Rinse Tank Basket Being Removed
3
Turn off the facility power safety
disconnect for the Aquastorm 200
™
system.
4
Remove rear access panels, tank lids and
basket assemblies
The recirculation filters are located
toward the rear side of the tanks. Remove
filters from the rear of the cabinet
enclosure.