Aquastorm 200
2-2 System Preparation
1.2
OPTIONAL PH MONITOR
SETUP
CAUTION
It is imperative to maintain buffer
solution moisture on the pH electrodes
to prevent drying out. After removing
the pH buffer cap, proceed
immediately to System Start Up to fill
the tanks.
Do Not dispose of the pH buffer cap.
It may be necessary to reuse it in the
future.
The pH probe is supplied with a blue plastic cap
containing a buffer solution to prevent drying of
the pH probe electrode. If the electrode is
permitted to dry out it will become inoperable.
The blue plastic cap is located over the end of
the probe.
To remove the buffer solution cap:
1
Remove the wash tank rear maintenance
access panel.
2
Remove the wash tank cover from the top
of the wash tank.
3
Remove the blue buffer solution cap from
the tip of the pH probe inside the wash
tank.
•
Optional Chemical Isolation operating
level indicator illuminates green (if tank is
full)
•
Wash Tank temperature indicator
illuminates green (if tank is not up to
temperature)
•
Rinse Tank temperature indicator
illuminates green (if tank is not up to
temperature)
•
Optional Chemical Isolation Tank
temperature indicator illuminates green
(if tank is not up to temperature)
•
Conveyor Off indicator illuminates red
•
Optional Interior Lights illuminate
•
Internal Hard Drive boots up
•
High temperature monitors (West 6700)
in the low voltage electrical enclosure
illuminate.
Temperature Set Points
Ensure that the correct Set points for the
Wash, Rinse and Optional Chemical
Isolation tanks as well as high and low
deviation levels
have been set via the
LCD (Liquid Crystal Display) interface
keypad.
Optional Auto Detergent
Injection System
If your system is configured with the
Optional Auto Detergent Injection
system, ensure that the suction line of the
detergent injection system is inserted into
the detergent reservoir prior to operation.
Optional pH Monitor
If your system is configured with the
Optional pH Monitor ensure that the
Buffer Solution Cap is removed from the
end of the pH probe prior to filling the
Wash tank.