4-8 Maintenance
Aquastorm 200
Wash, Rinse and Optional
Chemical Isolation Tanks
NOTE
Saponifiers contain
defoamers which defoam surface
water. When applying Saponifier
in any application do not skim any
residue from the water surface
except for when performing
maintenance procedures and when
the tank is to be drained.
Excessive foaming can occur
during operation if the defoamers
are removed.
Inspect the cleanliness of the water in the Wash,
Rinse and optional Chemical Isolation tanks.
Drain the tank(s) if the water is contaminated.
Access the Wash, Rinse and Chemical Isolation
tanks via the rear access panels. Remove the rear
access panels; Wash, Rinse and Chemical
Isolation tank lids and catch screens, and to gain
access to the tanks.
The Aquastorm 200™
Wash, Rinse and Chemical
Isolation tank drains are controlled via brass
solenoid valves and are located on the system
drain plumbing at the under side of the system.
The wash, rinse and chemical isolation tank
drains are activated by the operator via the front
control panel membrane keypad.
NOTE
If your process is using deionized
water in the wash and rinse tanks
the tanks must be rinsed with
deionized water. Rinsing with tap
water in this type of application
will contaminate the process.
Once the wash, rinse and optional chemical
isolation tanks are drained, rinse the tanks using
a hose with spray nozzle. Rinse until the tank(s)
are clean and free from debris.
Turn off the wash, rinse and chemical iIsolation
tank drain valves.
Inspect the drain screens and pump filters in the
wash, rinse and chemical isolation tanks.
Wash Section Rear Access Panel
Rinse Section Rear Access Panel
Optional Chemical Isolation
Section Rear Access Panel