Aquastorm 200
Maintenance 4-57
M8 Flat & Lock Washer
M8 Nut
3/4" Spacer
M8 Flat Washer
M8 x 50 Hex Head Bolt
perform steps 10A and 10B, then proceed
to step 11.
9
Locate the M8 hardware securing the
Slide-Out blower trays; using a 13 mm
open end wrench and a 13 mm socket with
ratchet, remove the M8 x 50 hex head
bolt, M8 nut, M8 lock and flat washers,
and 3/4" spacers from either side of the
tray closest to the rear of the machine.
10A
Use a
7
/
16
" open end wrench to loosen and
remove the three (3) front most blower
base plate mounting bolts (M8 x 35) of the
four (4) that are securig it.
10B
Pivot the blower to the right as far as
possible to allow access to the blower belt
guard.
L
L
oosen Hose Clamp Here
oosen Hose Clamp Here
then lift R
then lift R
ubber Union from
ubber Union from
Blower Housing
Blower Housing
Belt Guard
Belt Guard
11
Locate the belt guard on the turbine
blower.
5
Access the blower assembly at the rear of
the machine. Use a
5
/
16
" nut driver to
loosen the hose clamp on the rubber union
at the blower housing.
6
Lift the rubber union from the blower
housing to free the blower assembly for
movement.
7
Allow the blower manifold assembly to
hang freely from the rear bulkhead.
8
For systems configured with the Optional
Slide-Out Access for the blowers, perform
step 9, then proceed to step 11.
For systems configured without the
Optional Slide-Out Access for the blowers
Содержание Aquastrom 200
Страница 26: ...Aquastorm 200 Overview 1 21 Optional Sump Pump 61 6 cm 24 in L x 42 5 cm 16 6 in W x 61 8 cm 24 in H ...
Страница 48: ......
Страница 142: ...Aquastorm 200 Maintenance 4 49 ...