Aquastorm 200
4-50 Maintenance
3.5
OPTIONAL PHOTO SENSOR
ADJUSTMENT
Alignment
The optional photo sensor emitter and detector
located at the entrance of the system must be
aligned to provide proper detection of product
entering the Aquastorm 200
™
Aqueous Cleaner.
1
Turn on the facility power at the safety
disconnect for the Aquastorm 200
™
.
2
Press the
Power On Control via the
membrane keypad to activate system
power.
The Power On indicator illuminates to
indicate power is activated.
3
Locate the photocell emitter and reflector
at the conveyor entrance end (mounted on
the optional inlet conveyor).
4
Remove any objects obstructing the
emitter path.
5
Observe the green LED on the photocell
emitter.
6
Adjust the photocell emitter and reflector
so that the green indicator on the emitter
illuminates with normal movement around
the entrance end of the conveyor.
7
Place product having the lowest
components expected to be processed in
the path of the photocell emitter and
reflector.
Photocell Emitter
Sensitivity Adjustment Screw
Photocell Emitter
Green/ Red LED Indicator
Photocell Reflector
8
Loosen the screws securing the photocell
emitter mounting bracket and photocell
reflector mounting bracket, enough to
allow slight vertical movement.
9
Slowly lower the emitter and reflector
until the LED on the photocell emitter is
no longer illuminated.
10
Secure the mounting hardware on both
the photocell emitter and photocell
reflector mounting brackets, taking
caution not to disturb the correct
placement of the photocell components.
11
After securing the mounting hardware,
verify the green LED is still in operation
by removing the product from the
photocell path.
The green LED on the photocell emitter
should illuminate when the PWA is
removed.