Aquastorm 200
4-54 Maintenance
12
Using a
3
/
16
Allen wrench, loosen the two
(2)
1
/
4
-20 x
3
/
4
" socket head cap screws
securing the turbine blower belt guard,
then remove the guard.
Turbine Blower
Blower Motor
Blower Belt Cover
3/16" Allen Wrench
1/4-20 x 3/4" Socket Head Screws
13
Use a
3
/
4
" socket with
3
/
8
" ratchet with
2.0" extension to loosen the four (4) hex
head bolts behind the blower motor pulley.
Turn the motor pulley to aligh the slotted
access hole with the hex head bolt, then
insert the socket through the slotted hole
on the motor pulley.
14
Loosen the bolts only enough to allow the
blower motor to slide toward the blower
housing when the tension adjust screw is
adjusted in that direction.
Do not
remove the four hex head bolts.
15
Turn the tension adjust screw
counterclockwise, using a
9
/
16
" open end
wrench, allowing the blower motor to slide
toward the blower housing.
This relieves the tension on the belt.
16
Turn the tension adjust screw until enough
tension is relieved to remove the belts.
Tension Adjust Screw
3-Strand Belt
Blower Motor Pulley
Blower Pulley
Slotted Access Holes
Turn Pulley to Align Slotted
Holes with Hex Head Bolts
BLOWER WITH BELT COVER REMOVED
(Configuration Shown with a 3-Strand Belt)
Before replacing the belt with a new one,
refer to the Turbine Blower Pulley
Alignment Procedure provided in this
section of the manual. This is to verify
that the pulley alignment has not
changed. If the pulleys are out of
alignment, follow the procedure
completely.
Contact Electrovert Technical Support
for correct identification of the
replacement belt for your turbine blower.
Содержание Aquastrom 200
Страница 26: ...Aquastorm 200 Overview 1 21 Optional Sump Pump 61 6 cm 24 in L x 42 5 cm 16 6 in W x 61 8 cm 24 in H ...
Страница 48: ......