Appendix B: Transmitter Installation
CommPact Installation Manual
88
For
maximum
pet
immunity
the
following
guidelines
are
recommended:
Mount
the
center
of
the
detector
at
a
height
of
2.0m.
Do
not
aim
the
detector
at
stairways
that
can
be
climbed
by
an
animal.
Avoid
a
location
where
an
animal
can
come
within
1.8m
(6
ʹ
)
of
the
detector
by
climbing
on
furniture,
boxes
or
other
objects.
Installation Procedure
To
install
PIR
detectors:
1.
Open
the
housing
by
removing
the
front
cover.
To
do
so,
insert
a
screwdriver
in
the
release
slot
(located
at
the
bottom
of
the
detector
between
the
front
and
back
cover).
Turn
the
screwdriver
90º
to
release
the
cover.
2.
Remove
the
PCB
by
turning
counter
‐
clockwise
and
removing
the
ʹ
PCB
Screw
ʹ
.
Do
not
touch
the
face
of
the
PYRO
sensor.
3.
Apply
battery
power
by
removing
the
isolator
that
separates
the
battery
from
the
contacts
on
the
battery
holder.
4.
From
the
Programming
menu,
select
Devices,
Zones
[911]
and
select
the
zone
to
which
you
want
to
register
the
transmitter.
5.
Cause
a
Tamper
or
Alarm
transmission
and
wait
for
the
receiver
to
indicate
that
the
transmitter
has
been
registered
successfully.
When
Save?
appears
on
the
Control
System’s
LCD
display,
press
ʹ√ʹ
.
Write
the
number
of
the
zone
and
the
transmi
tt
er
number
(if
applicable)
on
the
sticker
provided.
Affix
the
sticker
inside
the
front
cover
for
future
reference.
Alternatively,
the
Detector
can
be
registered
to
the
receiver
by
manually
entering
the
transmitter
ʹ
s
serial
number.
6.
Choose
an
appropriate
mounting
height
from
2.2
–
2.5
and
test
the
transmitter
from
the
exact
mounting
position
before
permanently
mounting
the
unit.
If
you
choose
mounting
height
other
than
recommended
(which
is
not
advised),
please
perform
a
walk
test
to
check
the
lens
coverage.
The
recommended
mounting
height
is
the
best
in
terms
of
detection
area.
7.
Knock
out
the
mounting
holes
and
attach
the
base
to
the
wall.
8.
If
using
the
rear
tamper
switch,
insert
a
screw
into
the
rear
tamper
mounting
hole
located
in
the
center
of
the
back
cover.
When
the
detector
is
removed
from
the
wall,
the
screw
causes
the
tamper
release
to
break
away
from
the
back
cover
and
the
rear
tamper
switch
is
released.
Figure B- 2: Back Tamper Release
9.
Mount
the
PCB
on
the
base
cover
and
replace
the
PCB
Screw.
10.
Replace
the
front
cover.
Back tamper
mounting hole
Содержание Commpact
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...
Страница 160: ......