Hata! Burada görünmesini istedi
ğ
iniz metne Heading 1 uygulamak için Giri
ş
sekmesini kullan
ı
n.
Hata! Burada
görünmesini istedi
ğ
iniz metne Heading 1 uygulamak için Giri
ş
sekmesini kullan
ı
n.
CommPact Installation Manual
58
9.6.4.
PGM Cut-off
The
PGM
Cut
‐
off
is
the
duration
for
which
the
PGM
is
activated.
Certain
Output
Trigger
types
are
deactivated
after
the
PGM
Cut
‐
off
time
has
expired–
see
p.
56,
Table
9
‐
1.
For
those
Output
Trigger
types
that
are
not
affected
by
the
PGM
Cut
‐
off,
there
is
no
need
to
program
this
option.
If,
for
example,
Output
Trigger
option
is
set
to
Full
Arm,
and
PGM
Cut
‐
off
time
is
060
seconds;
then
PGM
is
activated
by
Full
Arming
and
deactivated
by
disarming
or
by
PGM
Cut
‐
off
Time,
whichever
comes
first.
If
this
option
is
set
to
ʺ
000
ʺ
(Continuous
activation),
PGM
is
activated
by
Full
Arming,
and
deactivated
by
disarming.
To
program
the
PGM
Cut
‐
off
time:
1.
From
the
Programming
menu,
select
System
Options,
PGM
Options,
and
PGM
Cut
‐
off
[94064].
2.
Enter
a
PGM
Cut
‐
off
time
(001
‐
255
seconds
or
000
for
continuous
activation),
then
press
ʹ√ʹ
.
9.7.
"No Arm" Indication
The
ʺ
No
Arm
ʺ
indication
is
a
feature
designed
to
inform
the
central
station
that
the
system
has
not
been
armed
for
a
specified
period
of
time.
To
define
the
ʺ
No
Arm
ʺ
indication
interval:
1.
From
the
Programming
menu,
select
System
Options,
No
Arm
Ind.
[9408].
2.
Select
1
Week,
2
Weeks,
3
Weeks,
4
Weeks
or
Disabled.
The
No
Arm
event
message
is
an
unclassified
event.
This
means
that
it
does
not
belong
to
any
event
group.
If
the
No
Arm
option
is
programmed
with
any
option
other
than
ʺ
Disabled
ʺ
,
the
event
message
will
be
sent.
9.8. Jamming
Detection
The
system
is
able
to
detect
RF
Jamming
that
is
usually
caused
by
an
intruder
attempting
to
compromise
the
security
system.
To
program
the
Jamming
Detection
setting:
1.
From
the
Programming
menu,
select
System
Options,
Jamming
Det.
[9409].
2.
Select
Enabled
or
Disabled.
9.9.
"No Motion" Time
The
No
Motion
feature
is
designed
to
monitor
the
activity
of
disabled
or
elderly
people.
If
a
detector
defined
as
No
Motion
(see
p.
35,
7.3.1
Zone
Type):
When
the
system
is
disarmed,
and
the
detector
has
not
been
triggered
within
a
pre
‐
defined
period
of
time
(00:00
to
72:00
hours),
a
No
Motion
event
message
is
sent
to
the
central
station.
When
the
system
is
armed,
this
zone
behaves
as
Normal.
The
No
Motion
zone
must
be
included
in
this
arming
mode
–
see
p.
42,
7.3.2
Arm
Set.
To
program
the
No
Motion
time:
1.
From
the
Programming
menu,
select
System
Options,
No
Motion
[9410].
2.
Enter
the
No
Motion
time
value
between
00:00
and
72:00.
To
disable
the
No
Motion
feature,
enter
00:00.
press
ʹ√ʹ
.
Содержание Commpact
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...
Страница 160: ......