Appendix B: Transmitter Installation
CommPact Installation Manual
108
The
unit
must
be
fixed
to
a
secure
base.
7.
Once
you
have
mounted
the
detector,
it
is
necessary
to
adjust
the
detector’s
sensitivity
as
follows:
o
Make
sure
that
the
Tamper
switch
is
open
and
insert
the
Sensitivity
Adjustment
jumper;
the
LED
flashes
once
every
few
seconds
to
indicate
that
the
detector
is
in
Adjustment
mode.
o
Strike
the
protected
door
or
window
at
the
furthest
point
away
from
the
detector
with
a
screwdriver
handle
or
cushioned
tool;
the
LED
flashes
every
few
seconds
to
indicate
the
sensitivity
level.
1
flash
=
test
failed
(sensitivity
too
low)
2
flashes
=
“Normal”
sensitivity
(recommended)
3
flashes
=
“High”
sensitivity
Fast
continuous
flashing
=
test
failed
(sensitivity
too
high).
o
If
required,
turn
the
Sensitivity
Adjustment
potentiometer
clockwise
to
increase
sensitivity
and
counter
‐
clockwise
to
reduce
sensitivity.
o
Repeat
the
sensitivity
adjustment
test
until
you
achieve
the
required
sensitivity
level
(i.e.
the
LED
flashes
twice
or
three
times
every
few
seconds).
8.
After
you
have
adjusted
the
sensitivity,
repeat
the
test
once
more
and,
while
the
LED
is
flashing
as
required,
press
the
Tamper
switch
in
order
to
save
the
sensitivity
setting.
You
can
press
the
tamper
switch
once
or
just
close
the
housing.
9.
When
you
press
the
Tamper
switch
to
save
the
sensitivity
setting,
the
detector
automatically
switches
from
Adjustment
mode
to
Test
mode.
In
Test
mode,
you
can
test
the
sensitivity
of
the
detector
by
striking
the
door
or
window
frame.
If
the
impact
detected
by
the
detector
is
enough
to
generate
an
alarm,
the
LED
is
lit.
Make
certain
that
striking
the
door
or
window
frame
softly
does
not
generate
an
alarm.
In
Test
mode,
there
is
no
four
minute
alarm
delay
and
alarm
detection
does
not
result
in
the
detector
sending
an
alarm
transmission.
10.
Terminate
Test
mode
by
closing
the
Tamper
switch.
Test
mode
is
automatically
terminated
after
approximately
five
minutes.
11.
Remove
the
Sensitivity
Adjustment
jumper
and
place
it
over
one
pin
for
storage.
12.
Close
the
front
cover
of
the
EL
‐
2607.
Table B- 3: Operation Mode Summary
Operation
Mode
Description Activation
Registration
A transmission is sent every few
seconds allowing the detector to be
registered to the receiver.
Activated by applying battery power.
Registration mode may be terminated by
pressing the Tamper switch or is
automatically terminated after 5 minutes.
Adjustment
Striking the protected door or
window frame indicates the
detector’s sensitivity setting.
Activated by installing the Sensitivity
Adjustment jumper while the Tamper switch
is open. Pressing the Tamper switch during
Adjustment mode saves the adjustment
setting.
Test
Striking the protected door or
window frame indicates whether the
impact would generate an alarm.
Activated automatically when you press the
Tamper switch to save the adjustment
setting. Test mode may be terminated by
Содержание Commpact
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...
Страница 160: ......