Hata! Burada görünmesini istedi
ğ
iniz metne Heading 1 uygulamak için Giri
ş
sekmesini kullan
ı
n.
Hata! Burada
görünmesini istedi
ğ
iniz metne Heading 1 uygulamak için Giri
ş
sekmesini kullan
ı
n.
CommPact Installation Manual
47
7.6. Repeaters
Repeaters
are
designed
to
extend
the
wireless
range
of
the
Control
System.
Up
to
four
repeaters
may
be
registered
to
the
system
with
a
maximum
of
32
transmitters
associated
with
each
receiver.
For
information
on
registration,
deletion,
and
descriptor
editing,
see
p.
135.
7.7. Wireless
Siren
The
Control
System
sends
alarm
and
arm
status
information
to
the
wireless
siren’s
receiver.
This
requires
that
you
register
the
Control
System
to
the
wireless
siren’s
receiver.
To
register
the
Control
System
to
the
wireless
siren’s
receiver:
1.
Set
the
wireless
siren’s
receiver
to
Registration
mode
–
refer
to
the
siren’s
installation
instructions
for
further
information.
2.
Activate
the
siren
using
the
WL
Siren
Test
feature
–
see
p.29,
4.7.3
Wireless
Siren
Test.
3.
Activate
the
siren
again;
the
Control
System
is
registered
to
the
siren’s
receiver.
2
‐
way
sirens
must
be
registered
to
the
Control
System.
For
information
on
registration
and
deletion,
see
p.
39,
7.2.1
Registering
Wireless
Devices,
and
p.
39,
7.2.2
Deleting
Wireless
Devices.
7.7.1.
Wireless Siren Type
The
Control
System
supports
2
‐
way
wireless
sirens.
For
this
feature
to
function
correctly,
you
must
define
the
wireless
siren
type
in
programming.
The
following
options
are
available:
2
‐
Way
Siren
–
if
using
the
EL
‐
2626AC
wireless
siren.
2
‐
Way
Siren/Kpd
–
if
using
the
EL
‐
2626AC
wireless
siren
and
EL
‐
2621
wireless
indication
keypad.
To
program
the
wireless
siren
type:
1.
From
the
Programming
menu,
select
Devices,
Siren,
WL
Siren
Type
[9152].
2.
Select
a
siren
type
or
No
WL
Siren
if
no
siren
is
installed.
7.7.2.
Wireless Siren Delay
The
Wireless
Siren
Delay
is
the
period
of
time
during
which
the
wireless
siren
is
not
sounded
after
an
alarm
is
triggered
by
Normal,
Follower
or
24Hr
zones.
This
feature
is
implemented
only
when
the
system
is
not
fully
armed.
During
the
Wireless
Siren
Delay,
the
Control
System’s
built
‐
in
siren
is
sounded
but
the
alarm
report
is
not
sent
until
the
delay
has
expired.
This
gives
the
user
enough
time
to
disarm
in
the
event
that
the
alarm
was
accidentally
triggered
during
Part
or
Perimeter
arming.
If
the
user
disarms
the
system
during
the
Siren
Delay,
an
alarm
event
is
not
reported
to
the
central
station.
To
program
the
Wireless
Siren
Delay
time:
1.
From
the
Programming
menu,
select
Devices,
Siren,
WL
Siren
Delay
[9153].
2.
Enter
a
Siren
Delay
time
(00
‐
63
seconds),
then
press
ʹ√ʹ
.
Содержание Commpact
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...
Страница 160: ......