Appendix B: Transmitter Installation
CommPact Installation Manual
92
indicate
that
the
transmitter
has
been
registered
successfully.
Alternatively,
the
EL
‐
2650XL
can
be
registered
to
the
receiver
by
manually
entering
the
transmitter
ʹ
s
serial
number.
The
receiver
allocates
a
transmitter
number
to
each
registered
unit.
Write
this
number
and
the
number
of
the
zone
on
the
sticker
provided.
Affix
the
sticker
inside
the
front
cover
for
future
reference.
3.
After
a
warm
‐
up
period
of
130
sec.
indicated
by
both
LEDs
ʹ
blinking,
the
detector
automatically
enters
Radio
Mode
for
4
minutes
approximately
and
sends
transmissions
every
8
seconds,
then
it
enters
Regular
mode
–
see
Operation
and
Adjustment,
Selectable
Operation
Modes
below.
4.
Knock
out
the
mounting
holes
and
test
the
transmitter
from
the
exact
mounting
position
before
permanently
mounting
the
unit.
The
EL
‐
2650XL
can
be
wall
or
ceiling
mounted.
The
ʺ
Alarm
ʺ
arrow
on
the
PCB
(see
Figure
B
‐
5
and
Figure
B
‐
6)
must
point
inward
(i.
e.
towards
the
protected
area).
The
recommended
height
is
2.2
m.
If
you
choose
mounting
height
other
than
recommended
(which
is
not
advised),
please
perform
a
walk
test
to
check
the
lens
coverage.
The
recommended
mounting
height
is
the
best
in
terms
of
detection
area.
5.
Attach
the
base
to
the
wall
with
two
screws.
If
using
the
Back
Tamper
switch,
insert
a
screw
into
the
Back
Tamper
hole
(see
Figure
B
‐
7)
instead
of
the
lower
mounting
hole.
When
the
detector
is
removed
from
the
wall,
the
screw
causes
the
tamper
release
to
break
away
from
the
back
cover
and
the
Back
Tamper
switch
is
released.
Figure B- 7: Back Tamper Release
6.
Mount
the
PCB
at
the
required
setting
using
the
horizontal
adjustment
scale
and
tighten
the
PCB
screw
–
see
Operation
and
Adjustment,
PCB
Adjustment
below.
Attach
the
front
cover
and
replace
the
cover
screw.
Operation and Adjustment
PCB Adjustment
PCB
adjustment
enables
you
to
angle
the
infrared
beams
by
changing
the
position
of
the
pyro
element
in
relation
to
the
lens.
To
adjust
the
PCB,
loosen
the
PCB
screw
and
slide
the
PCB
to
the
required
position
using
the
PCB
adjustment
scale
as
a
guide.
After
adjusting
the
board,
tighten
the
PCB
screw.
Slide
the
board
towards
‐
2
to
position
the
beams
closer
to
the
wall.
Slide
the
board
towards
+2
to
position
the
beams
further
away
from
the
wall.
For
the
correct
PCB
adjustment,
you
must
take
into
account
the
distance
of
the
detector
from
the
wall
and
the
distance
of
the
protected
door/window
from
the
detector
–
seeTable
B
‐
2
as
illustrated
in
Figure
B
‐
8
are
relevant
both
to
wall
and
ceiling
mounting.
Back tamper
mounting hole
Содержание Commpact
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...
Страница 160: ......