CommPact Installation Manual
17
For
this
feature
to
function,
Trouble
Tones
must
be
enabled
in
programming
–
see
p.
51,
8.6.1
System
Trouble
Tones.
System
trouble
tones
are
not
sounded
from
10:00pm
to
7:00am
so
as
not
to
disturb
household
members
who
may
be
asleep.
However,
you
can
program
the
system
to
immediately
annunciate
telephone
trouble
at
all
times
–
see
p.
51
8.6.2
Telephone
Trouble
Tones.
3.5.2.
Vocal Message Annunciation
Certain
versions
of
the
CommPact
Control
System
hardware
support
vocal
annunciation
of
system
status.
If
this
feature
is
enabled
in
programming
(see
p.
59,
9.10
Vocal
Messages),
the
system
plays
short
messages
to
indicate
arming,
disarming,
bypassed
zones,
system
trouble,
message
waiting,
and
water
alarm.
The
availability
of
the
Vocal
Message
annunciation
feature
is
hardware
dependent.
3.5.3.
Alarm Sounding Patterns
The
following
table
summarizes
the
system’s
various
alarm
patterns.
Table 3-7: Alarm Patterns
Alarm
Alarm Pattern Description
Sounding
Device
Burglary
ON (continuously)
Siren
Fire
ON - ON - ON, 1.5-second pause, ON - ON – ON...
Siren
Gas
ON - ON - ON - ON (short bursts), 5 second pauses, ON - ON - ON -
ON...
Siren
Medical
ON (continuously) – only applicable for Medical alarm from zone
Siren
Flood/
Environmental
4 rapid tones sounded once per minute (same as Trouble tones)
Buzzer
3.6.
Arming and Disarming
The
following
section
explains
how
to
arm
and
disarm
the
Control
System
using
the
front
panel
keypad
or
Wireless
Keypad:
3.6.1.
Arming
You
have
three
arming
modes
available:
full,
part,
and
perimeter.
Figure
3
‐
4
illustrates
the
three
arming
modes.
In
each
diagram,
the
protected
area
is
shaded.
Full Armed
Part Armed
Perimeter Armed
Figure 3-4: Arming Modes
The
arming
options
are
entirely
flexible.
You
can
program
each
detector
to
be
included
in
any
combination
of
the
three
arming
modes
–
see
p.
42,
7.3.2
Arm
Set.
Additionally,
each
arming
mode
has
a
separate
exit
and
entry
delay.
Содержание Commpact
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...
Страница 160: ......