Appendix B: Transmitter Installation
CommPact Installation Manual
127
Typical
carbon
monoxide
gas
problems
are
summarized
here:
Equipment
problems,
due
to
defects,
poor
maintenance,
damaged
and
cracked
heat
exchangers
Collapsed
or
blocked
chimneys
or
flues,
dislodged,
disconnected
or
damaged
vents
Downdraft
in
chimneys
or
flues.
This
can
be
caused
by
very
long
or
circuitous
flue
runs,
improper
location
of
flue
exhaust
or
wind
conditions
Improper
installation
or
operation
of
equipment,
chimney
or
vents
Air
tightness
of
house
envelop/inadequate
combustion
of
air
Inadequate
exhaust
of
space
heaters
or
appliances
Exhaust
ventilation/fireplace
competing
for
air
supply
Potential
sources
of
carbon
monoxide
in
your
home
or
office
include
clogged
chimney,
wood
stove,
wood
or
gas
fireplace,
automobile
and
garage,
gas
water
heater,
gas
appliance,
gas
or
kerosene
heater,
gas
or
oil
furnace
and
cigarette
smoke.
Selecting the Installation Location
Since
CO
gas
moves
freely
in
the
air,
the
suggested
location
is
in
or
as
near
as
possible
to
sleeping
areas
of
the
home,
30
cm
(12
inch)
below
the
ceiling
.
For
maximum
protection,
a
CO
detector
should
be
located
outside
the
primary
sleeping
areas
or
on
each
level
of
your
home
(see
Figure
B
‐
43
for
suggested
locations).
CARBON MONOXIDE DETECTOR
GROUND
FLOOR
BASEMENT
KITCHEN
GARAGE
BEDROOM
BEDROOM
BEDROOM
Figure B- 43: Selecting the Installation Location
This
device
is
not
suitable
for
installation
in
a
hazardous
location,
as
defined
by
the
US
National
Electrical
Code.
Do
not
place
the
detector
in
the
following
areas:
Where
the
temperature
may
drop
below
4ºC
(39ºF)
or
exceed
38ºC
(100ºF).
Near
paint
thinner
fumes
Within
1.5
meter
(5
feet)
of
open
flame
appliances
such
as
furnaces,
stoves
and
fireplaces
In
exhaust
streams
from
gas
engines,
vents,
flues
or
chimneys
Do
not
place
in
proximity
to
an
automobile
exhaust
pipe;
this
will
damage
the
detector
Содержание Commpact
Страница 84: ...Appendix A Menu Structure CommPact Installation Manual 80 Appendix A Menu Structure ...
Страница 85: ...Appendix A Menu Structure CommPact Installation Manual 81 ...
Страница 86: ...Appendix A Menu Structure CommPact Installation Manual 82 ...
Страница 87: ...Appendix A Menu Structure CommPact Installation Manual 83 ...
Страница 88: ...Appendix A Menu Structure CommPact Installation Manual 84 ...
Страница 89: ...Appendix A Menu Structure CommPact Installation Manual 85 ...
Страница 90: ...Appendix A Menu Structure CommPact Installation Manual 86 ...
Страница 160: ......