No heat:
If the control appears to be operating normally, but the
bake and broil burners do not heat:
1. Program the control for bake and check to see if
the bake igniter is glowing. If the igniter is not glowing
go to step 3. If the igniter is glowing check the
manual gas shut-off for the oven to be sure gas is
being supplied to the safety valve. Then remove the
bake igniter, connect it to 120 VAC and measure
the current flow through the igniter. If the current
flow is less than 3.2 amps replace the igniter. If the
current flow is 3.2 or more check the wiring in the
bake circuit for a poor connection.
2. Program the control for broil and check to see if the
broil igniter is glowing. If the igniter is not glowing
go to step 4. If the igniter is glowing remove the
igniter, connect it to 120 VAC and measure the
current flow through the igniter. If the current flow is
less than 3.2 amps replace the igniter. If the
current flow is 3.2 or more check the wiring in the
broil circuit for a poor connection.
3. Go to the back of the oven control, disconnect the
15 pin plug from the control and measure the voltage
drop between pins 1 and 4 in the 15 pin plug. If the
meter reads 120 VAC the control is defective. If the
meter reads zero the bake igniter, safety valve or
the wiring in the oven circuit is open. Go to step 5.
4. Go to the back of the oven control disconnect the
15 pin plug from the control and measure the voltage
drop between pins 2 and 4 in the 15 pin plug. If the
meter reads 120 VAC the control is defective. If the
meter reads zero the broil igniter, safety valve or the
wiring in the broil circuit is open. Go to step 5.
5. Disconnect the wires from the igniter and check it
for continuity with an Ohmmeter. If the meter reads
open replace the igniter. If the meter shows
continuity check the continuity of the safety valve.
If the meter reads open replace the safety valve. If
the meter show continuity one of the wires in the
circuit is open.
If the control appears to be operating normally, and the
broil burner operates but the bake burner does not heat:
1. Program the control for bake and check to see if
the bake igniter is glowing. If the igniter is not glowing
go to step 2. If the igniter is glowing check the
manual gas shut-off for the oven to be sure gas is
being supplied to the safety valve. Then remove the
bake igniter, connect it to 120 VAC and measure
the current flow through the igniter. If the current
flow is less than 3.2 amps replace the igniter. If the
current flow is 3.2 or more check the wiring in the
bake circuit for a poor connection.
2. Go to the back of the oven control, disconnect the
15 pin plug from the control and measure the voltage
drop between pins 1 and 4 in the 15 pin plug. If the
meter reads 120 VAC the control is defective. If the
meter reads zero the bake igniter, safety valve or
the wiring in the oven circuit is open. Go to step 3.
3. Disconnect the wires from the igniter and check it
for continuity with an Ohmmeter. If the meter reads
open replace the igniter. If the meter shows
continuity check the continuity of the safety valve.
If the meter reads open replace the safety valve. If
the meter show continuity one of the wires in the
circuit is open.
If the control appears to be operating normally, and the
bake burner operates but the broil burner does not heat:
1. Program the control for broil and check to see if the
broil igniter is glowing. If the igniter is not glowing
go to step 2. If the igniter is glowing remove the
igniter, connect it to 120 VAC and measure the
current flow through the igniter. If the current flow is
less than 3.2 amps replace the igniter. If the
current flow is 3.2 or more check the wiring in the
broil circuit for a poor connection.
2. Go to the back of the oven control, disconnect the
15 pin plug from the control and measure the voltage
drop between pins 2 and 4 in the 15 pin plug. If the
meter reads 120 VAC the control is defective. If the
meter reads zero the broil igniter, safety valve or the
wiring in the broil circuit is open. Go to step 3.
3. Disconnect the wires from the igniter and check it
for continuity with an Ohmmeter. If the meter reads
open replace the igniter. If the meter shows
continuity check the continuity of the safety valve.
If the meter reads open replace the safety valve. If
the meter show continuity one of the wires in the
circuit is open.
Fan in oven does not run when speed bake switch is
turned on:
Note:
There is a six minute delay before the fan will
operate at the start of the speed bake program.
1. Remove power from the range and set the speed
bake switch to on. Disconnect the 15 pin plug from
the oven control and measure the resistance between
pins 14 and 15 (in the plug, not on the EOC).
If the
meter reads infinity, the speed bake switch or the
Содержание 30" GAS FREESTANDING RANGES
Страница 43: ...43 SAMPLE SCHEMATIC FOR ES100 CONTROL SYSTEM ...
Страница 50: ...50 SAMPLE SCHEMATIC FOR ES 200 CONTROL SYSTEM ...
Страница 60: ...60 SAMPLE SCHEMATIC FOR ES 300 CONTROL SYSTEM ...
Страница 72: ...72 SAMPLE SCHEMATIC FOR ES 400 CONTROL SYSTEM ...
Страница 84: ...84 SAMPLE SCHEMATIC FOR ES 450 CONTROL SYSTEM ...
Страница 93: ...93 Sample schematic for 36 gas range ...
Страница 130: ...130 NOTES ...
Страница 131: ...131 NOTES ...
Страница 132: ...132 ...