31
If air shutter needs adjusting, rotate the shutter to
allow more or less air into the burner tubes as
needed.
E. Convert Oven Burner Orifice
1. Remove storage drawer if equipped or lower
panel to gain access to oven burner spuds.
2. Remove oven bottom and oven burner baffle
located on top of burner. To remove oven bot-
tom, pull up at rear, disengaged front of bot-
tom from oven front frame, and pull the oven
bottom straight out of the oven. Remove
burner baffle so that the burner flame can be
observed.
3. Using ½” wrench, turn down the adjustable
spud which injects gas into the oven burner,
until snug against the LP metering pin. This
will be approximately 2 ½ turns.
Do Not Over-
tighten.
4. Push the BAKE TEMP button, then SET the
temperature to 300°F. Wait until burner starts
to cycle. To determine if the oven burner
flame is proper, observe the flame. It should
be steady with approximately 1" blue cones
and no yellow or orange flame tips.
Figure 14
5. If adjustment to the air shutter is necessary, lo-
cate oven burner air shutter, loosen shutter set
screw and adjust to obtain optimum flame (fig-
ure 14). This will normally be completely open
for LP gas. Tighten shutter set screw.
F. Convert Waist High Broiler Burner Orifice
Flame (Self-Clean Models Only)
Figure 15
1. Open oven door.
2. Locate broiler burner spud and turn down ap-
proximately 2 ½ turns so that spud is snug
against LP metering pin.
Do Not Overtighten.
3. To determine if burner flame is proper, push
the BROIL button, then turn the SET knob to
the LO setting, and observe broiler flame. It
should be steady and sharp with approximately
1" blue cones and no yellow or orange flame
tips.
4. If adjustment to the air shutter is necessary, lo-
cate oven burner air shutter, loosen shutter set
screw and adjust to obtain optimum flame (fig-
ure 14). This will normally be completely open
for LP gas. Tighten shutter set screw.
Pin
Nat
L.P.
Oven Burner Spud
Figure 13
Spud
Air Shutter
Spud
Nat.
L.P.
Pin
Содержание 30" GAS FREESTANDING RANGES
Страница 43: ...43 SAMPLE SCHEMATIC FOR ES100 CONTROL SYSTEM ...
Страница 50: ...50 SAMPLE SCHEMATIC FOR ES 200 CONTROL SYSTEM ...
Страница 60: ...60 SAMPLE SCHEMATIC FOR ES 300 CONTROL SYSTEM ...
Страница 72: ...72 SAMPLE SCHEMATIC FOR ES 400 CONTROL SYSTEM ...
Страница 84: ...84 SAMPLE SCHEMATIC FOR ES 450 CONTROL SYSTEM ...
Страница 93: ...93 Sample schematic for 36 gas range ...
Страница 130: ...130 NOTES ...
Страница 131: ...131 NOTES ...
Страница 132: ...132 ...