21
How to Convert the Range for use with LP/Propane
Gas
1. Convert the Pressure Regulator
To access the gas regulator, remove the storage drawer
or warmer drawer. If equipped with a storage drawer,
open and remove the drawer completely. For models
equipped with a storage drawer or front panel, remove the
storage or front panel and skip steps a & b below. For
models equipped with warmer drawer, follow all the
instructions below to remove the warmer drawer.
a.
Electrical Shock Hazard can occur
and result in serious injury or death. Disconnect
electrical power to the range before removing the
warmer drawer for servicing.
b. Locate glide lever on each side of drawer, pull up on
the left glide lever and push down on the right glide
lever (See Figure 1).
Figure 1
c. Pull the drawer away from the range (See Figure 2).
d. Remove the regulator access cover if equipped.
Do
not remove the Pressure Regulator or allow it to
turn.
e. Remove the dust protector from the cap. Using a 5/
8" wrench, unscrew the cap from the pressure
regulator.
Do not remove the spring from the
regulator.
f.
Turn the cap over so the hollow end faces outward.
Place the solid end of the cap into the loop end of the
dust protector (See Figure 3).
g. Replace the cap on the regulator. The letters LP
should be visible on the exposed end of the cap.
Snap the dust protector over the regulator cap.
Figure 2
Figure 3
Figure 4
Содержание 30" GAS FREESTANDING RANGES
Страница 43: ...43 SAMPLE SCHEMATIC FOR ES100 CONTROL SYSTEM ...
Страница 50: ...50 SAMPLE SCHEMATIC FOR ES 200 CONTROL SYSTEM ...
Страница 60: ...60 SAMPLE SCHEMATIC FOR ES 300 CONTROL SYSTEM ...
Страница 72: ...72 SAMPLE SCHEMATIC FOR ES 400 CONTROL SYSTEM ...
Страница 84: ...84 SAMPLE SCHEMATIC FOR ES 450 CONTROL SYSTEM ...
Страница 93: ...93 Sample schematic for 36 gas range ...
Страница 130: ...130 NOTES ...
Страница 131: ...131 NOTES ...
Страница 132: ...132 ...