21
PE
G7-1
X3-2
X3-1
X3-5
X3-4
PE
X10
X11
PE
G7-1
X3-2
X3-1
X3-5
X3-4
PE
X10
X11
3. MAKEREADY
Connection box
PE probe
Mains plug
X1
Mains plug
X1
Test object
Sense2
Connection box
Test object
Sense1
Sense2
Connection for ISO-Testing
See High Voltage test.
Connection for PE-Testing
Fig. 3.3b: Principle of connection PE - via box and PE-test probe (four
wire measuring)
Note:
Place the PE-probe in the fixture holder. No connection to the test
object chassis, has to be present.
Fig. 3.3a: Principle of connection PE - via box with-out test probe (four
wire measuring)
Note:
The connection to the object chassis should be switch-able by a
suitable switching element K1 (provision of material by customer). This is
required, to prevent a feedback of the test voltage (ISO-/HV test) to the
tester. X3-5/X3-4 are shorted inside the device by a relay to PE. Open the
connection to the object chassis over K1, before start up an ISO-/HV-test
and also before using the PE-test probe for PE-testing.
At using the PE-test probe
- no other connection to the object chassis,
has to be present (Fig. 3.4d). In case of other connections to the chassis,
it is possible to get significant measurement errors.
K1
Combi-tester G7-1G/-1H/-1T/-1U
Содержание G7-1G
Страница 5: ...5 1 INTRODUCTION free page Combi tester G7 1G 1H 1T 1U...
Страница 38: ...38 4 Operating modes 4 2 Normal Mode Test sequence Combi tester G7 1G 1H 1T 1U...
Страница 39: ...39 4 Operating modes 4 2 1 HV IS test normal mode Combi tester G7 1G 1H 1T 1U...
Страница 40: ...40 4 Operating modes 4 2 2 PE test normal mode Combi tester G7 1G 1H 1T 1U...
Страница 41: ...41 4 Operating modes 4 2 3 Normal mode input step Combi tester G7 1G 1H 1T 1U...
Страница 42: ...42 4 Operating modes 4 2 4 Normal mode output step Combi tester G7 1G 1H 1T 1U...
Страница 43: ...43 4 Operating modes 4 2 4 Normal mode time step Combi tester G7 1G 1H 1T 1U...
Страница 44: ...44 4 Operating modes 4 3 Fast Start Mode test sequence Combi tester G7 1G 1H 1T 1U...
Страница 45: ...45 4 Operating modes 4 3 1 Fast Start Mode PE HV ISO Test Combi tester G7 1G 1H 1T 1U...