66
10. Menu System
Full-electronic HV-Tester F1-1x Typs
„Copy“
- creates a copy of the test plan marked. The device prompts
for the new test plan name. Then the test plan screen appears, see
chapter 10.7. „Test plan management“.
„Remove“
- deletes the test plan marked from the list (after prompt). At-
tention - a deleted test plan cannot be restored.
10.6.2
Import/export of test plans
"Import Export"
of test plans from/to a removalbe storage medium (e.g.
USB-stick).
Prerequisite:
At the storage medium exists a folder with the name "test-
plans". In this folder must be stored the test plan files.
After the connection of the storage medium at USB-socket X8 (interface),
the both buttons "Import/Export" go active (reaction time approx. 5s).
Now the import / export of test plans is possible.
Note:
There is no plausibility check of the test plan files.
10.6.3
Test plan Version Major /Minor
The list shows the test plans and also all variants of the individual test
plans. To be able to include different test plan variants, the Major or Minor
number is advanced automatically at change of the test plan. Two steps
are distinguished.
Major
- Structural changes at the test plan
e.g. adding/removing a test step.
Example:
Test1 1 (Major) / 0 (Minor)
before change
Test1 2 (Major) / 0 (Minor)
after inserting another
test
step
Minor
- Default changes in the test plan,,
e.g. one or more default values (Tolerances) are changed.
Example:
Test1 1 (Major) / 0 (Minor)
before change
Test1 1 (Major) / 1 (Minor)
after the increase of
Imax at the HV test.
Minor is moved back to zero after a change of major.
Fig. 10.13a: Test plan list -Major/Minor