9.1
Agitation
Corrective action
Possible causes
Problem
Contact your GE representative
for service.
A fuse has blown and the agita-
tor is not powered.
The agitator does not start.
Check the weight interlock. See
Section 2.4 Interlocks, on
page 40
for more information.
Weight interlock is active.
Tap RESET on the local control
software home screen and start
the agitator when the system
has been restarted after emer-
gency shutdown.
Note:
The agitator cannot be started
while the system is in the state E
Stop Pressed.
The system is in the state of E
Stop Pressed.
Enable the agitator. See
FlexFactory Automation User
Manual for more information.
The agitator is not enabled.
The agitator does not start on
FlexFactory controlled mixer.
Tap RESET on the local control
software screen and start the
agitator when the system has
been restarted after emergency
shutdown.
Note:
The agitator cannot be started
while the system is in the state E
Stop Pressed.
The system is in the state of E
Stop Pressed.
1
Set the system to Auto
mode.
2
Specify the setpoint.
Note:
When the system is in Manual
mode the setpoint is ignored.
The system is in Manual mode
and cannot accept the setpoint.
Xcellerex XDUO 2500 Mixer Operating Instructions 29146667 AH
265
9 Troubleshooting
9.1 Agitation