V&T Technologies Co., Ltd.
http://www.ecodrivecn.com
Chapter 5 List of Parameters
45
Function
code
number
Function code
name
Factory
setting
Setting range
Unit
Property
Function code selection
User
setting
auxiliary calculation
4: Take maximum value;
5: Take minimum value
P1.05
Analog feedback
close loop control
main feedback
mode
1
1 ~ 4
/
×
1: AI1; 2: AI2;
3: AI3; 4: DI
P1.06
Analog feedback
close loop control
auxiliary feedback
mode
0
0 ~ 4
/
×
0: None;
1: AI1; 2: AI2;
3: AI3; 4: DI
P1.07
Analog feedback
close loop control
feedback main and
auxiliary calculation
0
0 ~ 5
/
×
0: Main + Auxiliary;
1: Main - Auxiliary;
2: Auxiliary-50%;
3: Main + Auxiliary-50%;
4: Take maximum value;
5: Take minimum value
P1.08
Process open loop
and close loop
composite operation
relationship
calculation
0
0 ~ 1
/
×
0:
Open loop frequency
re frequency after
closed loop PDI adjustment;
1: Open loop frequency reference
-
frequency after closed loop
PDI adjustment
Group P2 Key and Display Parameters
P2.00
Key-lock function
selection
0
0 ~ 3
/
○
0: No locking;
1: Locking all keys;
2: Locking all keys except MULTI
key;
3: Locking all keys except RUN
and STOP/RST keys
P2.01
Multi-function key
definition
1
0 ~ 8
/
○
0: No function;
1: Jog function;
2: Emergent shutdown 1(Stop in
shortest time);
3: Emergent shutdown 2
(Coast-to-stop);
4: Switch of input method of
running command
(Operation panel/Terminal/Host
computer);
5: Function code display switch
(fast/all);
6: Function code display
switching (different from
leave-factory/all);
7: Function code display
switching (the last changed 10
function codes/all);
8: Function code display
switching (P0.02 menu mode
switching)