V&T Technologies Co., Ltd.
http://www.ecodrivecn.com
Chapter 6 Parameter Description
92
The definition table of multifunctional analog output and pulse output is as follows:
Function
setup
Output signal
selection
Definition of analog output range
Definition of pulse output range
48
Output
frequency
Maximum frequency P0.11
corresponds to 10V/20mA.
Maximum frequency P0.11
corresponds to P7.10.
49
Setup
frequency
Maximum frequency P0.11
corresponds to 10V/20mA.
Maximum frequency P0.11
corresponds to P7.10
50
Output current
Two times rated current of inverter
corresponds to 10V/20mA.
Two times rated current of inverter
corresponds to P7.10
51
Motor current
Two times rated current of motor
corresponds to10V/20mA
Two times rated current of motor
corresponds to P7.10.
52
Output torque
Two times rated torque of motor
corresponds to 10V/20mA.
Two times rated torque of motor
corresponds to P7.10
53
Output voltage
Two times maximum output voltage
P0.12 corresponds to 10V/20mA.
Two times maximum output voltage
P0.12 corresponds to P7.10
54
Bus voltage
1000V corresponds to 10V/20mA
1000V corresponds to P7.10.
55
AI1
10V corresponds to 10V/20mA;
20mA corresponds to 5V/10mA.
10V corresponds to P7.10; 20mA
corresponds to 50% of P7.10.
56
AI2
The same as AI1
The same as AI1.
57
AI3
-10V ~ 10V corresponds to 0 ~
10V/20mA.
-10V ~ 10V corresponds to 0 ~
P7.10.
58
DI
Maximum input pulse frequency
P5.10 corresponds to 10V/20mA.
Maximum input pulse frequency
P5.10 corresponds to P7.10
59
Output power
2 times rated output power of motor
corresponds to 10V/20mA.
2 times rated output power of motor
corresponds to P7.10.
60
Host computer
percentage
10000 corresponds to10V/20mA.
10000 correspond to P7.10.
61
Heatsink
temperature
0 to 100
℃ corresponds to 0 to
10V/20mA
100
℃ corresponds to P7.10
62
Output
frequency 2
Maximum frequency P0.11
corresponds to 10V/20mA
Maximum frequency P0.11
corresponds to 10V/20mA
63~71 Reserved
Note: Output frequency indicate the output frequency of inverter, Output frequency 2 indicate the frequency
calculate by motor rotate speed.
P7.05
AO1 gain
0.0 ~ 200.0 %(100.0%)
P7.06
AO1 bias
0.0 ~ 200.0 %(0.0%)
P7.07
AO2 gain
0.0 ~ 200.0 %(100.0%)
P7.08
AO2 bias
0.0 ~ 200.0 %(0.0%)
P7.09
Selection of positive and negative gain and bias
0~1111(0000)