7.3.2.
Disarming delay (time for entry)
After clicking on this option an additional list will show, where you can set the time
for entry. Time after which alarm will be generated after delayed input had been
armed and partition to which delayed input belongs will not be disarmed.
7.3.3.
Arming input
After clicking on this option, partition arming input can be selected. To selected input,
arming device (remote controller receiver output or electronic keypad NO/NC output
for instance) is connected. When this input is armed, partition is armed (after Exit
Time, see below). When arming input is disarmed, partition is disarmed.
7.3.4.
Connected wired inputs
Assigning input to partition means that it is monitored only when partition to which
input belongs is armed. Input can be assigned up to one partition. Arming inputs
cannot be assigned to any partition. If input is not assigned to any partition, it acts
as 24 hours input
–
it is monitored regardless of partitions state.
7.4.
INPUTS/OUTPUTS
Communicators PX200NB have 9 inputs, two outputs. The "Input/Output" option
allows to configure the communicator in accordance with the requirements of the
user