background image

 

PX200NB 

 Manual 

Page 40 / 57 

 

8.1.2.

 

Events 

In this section, you can define the signals generated by the device to be transferred 
to  a  monitoring  station  by  every  device  added.  These  are  the  following  pieces  of 
information: 

 

On/Off, lock, tamper inputs, 

 

On/Off outputs, 

 

Power failures, 

 

Partitions arm/disarmed, 

 

Start/stop connection, on/off hook, dialing, 

 

Communicator states 

 

Communication with the monitoring center 

 information about update of time, 

configuration changes, start and finish of jamming, etc.; 

 

Information 

  information  about  the  start  of  a  control  panel,  CLIP,  about 

entering an incorrect code, etc.; 

 

8.2.

 

INITIAL STATES 

 

 

8.2.1.

 

Skip initial states 

This option allows for locking of sending of information on status of active inputs at 
power connection. Information on inputs will be sent to server after the first change 

from inactive to active status. 

Содержание PX200NB

Страница 1: ...2G 3G 4G COMMUNICATOR PX200NB Installation and programming manual Issue 2 0 Release date 05 09 2022 Firmware version 2 15 1 EBS Config 2 0 version 1 5 03 017...

Страница 2: ...nties either express or implicit including but not limited to any implied warranties of merchantability or fitness for a particular purpose unless it is required by relevant law The manufacturer reser...

Страница 3: ...Read configuration 19 6 5 6 Write configuration 19 6 5 7 Events history 20 6 5 8 Firmware update 20 6 5 9 Restoring factory settings 21 6 5 10 Connection settings 21 6 5 11 Application settings 23 6 5...

Страница 4: ...phone line 37 7 7 1 2 Disconnect external phone when server connected 37 7 7 1 3 Minimal time of external phone line voltage absence 37 7 7 1 4 Report off hook time longer than 38 7 7 1 5 Report when...

Страница 5: ...t mode 48 10 DEVICE PROGRAMMING 49 10 1 LOCAL PROGRAMING 49 10 1 1 The first programming of device 49 10 1 2 Reprogramming of device 50 11 RECEIVING OF SMS MESSAGE 51 11 1 DESCRIPTION OF THE PROTOCOL...

Страница 6: ...or connection of an alarm control panel s phone communicator This provides for a cheap system of data transmission Communication with a monitoring station follows by GPRS SMS mode This device provides...

Страница 7: ...iver 434 Mhz YES optional Max number supported keyfobs max 10 Power output 12V YES max load 200mA Serial interface RS232 RS485 lines RxD TxD RTS CTS transmission speed up to 115200bps Quantity of syst...

Страница 8: ...average max 3W 20W 230VAC Charging module functions protection against reverse battery connection AC failure signalization low battery no battery signalization protection against short circuit battery...

Страница 9: ...to prevent any faults or dead shorts Places of connections shall be protected against weather conditions According to the figure 1 terminals of communicator shall be connected to Terminal Connection d...

Страница 10: ...It may control external device Provides ground during activation R1 T1 Connection to alarm control panel phone communicator RING TIP Terminals for a PSTN telephone PGND Ground line for protecting an...

Страница 11: ...CONFIGURATION ONLY PX200NB 5R VERSION The device in version PX200NB 5R provides 2 additional virtual inputs that can be triggered by radio communicators The way of functioning should be configured by...

Страница 12: ...he channel is responsible for virtual input 10 Status LED on Pressing the remote control button program in the communicator memory LED turns off to exit the programming mode After the third STATUS LED...

Страница 13: ...nection of device to communication server OSM Server d waiting for moment when device indicates connection to server Note Connection to server is possible if the device was registered into it Registra...

Страница 14: ...PX200NB Manual Page 14 57 1111 SERVER 89 123 115 8 PORT 6780 APN general t mobile uk UN PW Where space character...

Страница 15: ...transmitting will follow only if an active state is on input and maintains during programmed minimum time Maintenance of active state longer than a minimum time will result in single indicating Anothe...

Страница 16: ...f EBS Config 2 0 mobile application 6 4 INSTALLATION If you have a SIM card with a pre programmed PIN code other than 1111 you should first configure the device using the EBS Config 2 0 by entering th...

Страница 17: ...shall be displayed on screen General menu is on the right side of the program screen 6 5 1 New configuration Opens a new set of parameters for the other kind of devices control panels and transmitter...

Страница 18: ...o remember each of them You can save on your hard drive all the device settings under a specific name and read them later This feature saves all information from the configuration windows to the drive...

Страница 19: ...tart downloading the settings saved in the communicator s memory with a message bar containing successful failed reading shown at the bottom of the app Data downloaded from the device can be stored an...

Страница 20: ...luetooth SP PROG BT MINI PROG BT and an RS232 port SP PROG SP PROG BT GD PROG After successful reading of the history you can search for events by entering names in the field marked with a magnifying...

Страница 21: ...em configuration All data you entered will be deleted and replaced with factory defaults The users and devices added to the communicators will not be deleted but their configuration will be deleted 6...

Страница 22: ...amming devices SP PROG equipped with a micro USB and RS232 ports with two COM ports assigned One is a configuration port for use during programming and the second is information port for use during mo...

Страница 23: ...a PC an open port will be shown in EBS Config assigned for communication between the programming device and a PC 6 5 11 Application settings In this window you can select one of application languages...

Страница 24: ...ice 7 1 SUMMARY This tab contains the following information Device model serial number installed modules Number of partitions created in the system and number of connected wired ports Number of wired...

Страница 25: ...RS232 Link control and Phone line An unauthorized attempt to access to this parameters causes error notification Default installer code 2222 7 2 3 User code This code is used to authenticate the user...

Страница 26: ...mes impossible Two additional fields will appear after activating this option React in case of no transmission for Here define the period of waiting until modem reset after detecting loss of network c...

Страница 27: ...NC output for instance is connected When this input is armed partition is armed after Exit Time see below When arming input is disarmed partition is disarmed 7 3 4 Connected wired inputs Assigning in...

Страница 28: ...sed for the whole time Line interruption causes its induction NO type input remains open It activates when closed EOL and DEOL single end of line resistor and double end of line resistor differ with 1...

Страница 29: ...peration modes available o always connection follows for indefinite time up to the moment of disconnection of power for module or remote command which switches output off o for the specific time conne...

Страница 30: ...puts and the Advanced outputs control at the same time In particular the basic configuration of existing options No GSM signal immediately after detection and Dependent on state transitions from non a...

Страница 31: ...Place the cursor in the line with a number and click Delete button to delete a number from the table The option Delete all will clean the whole table NOTE Authorisation of an incoming text message in...

Страница 32: ...fine the period for resetting the counter of sent text messages from 5 minutes to 3 days The following types of information may be subjected to limitations depending on the fact whether it is selected...

Страница 33: ...Such a case occurs if the condition imposed on the sender s phone number is met for at least two rules with the same number of the recipient NOTE The user takes responsibility for the proper administ...

Страница 34: ...section each event in the list can be assigned a predefined unique SMS notification zone When the event occurs an SMS notification with the selected content will be sent to defined numbers will be sen...

Страница 35: ...cted parameters shall correspond to RS 232 port settings in device which will be connected to the communicator Available parameters are shown in the table below Parameter Value Baud rate bits sec 1200...

Страница 36: ...control the other device 7 6 3 2 Disable data sending This option allows for lock of data sending to device connected to RS 232 port of communicator This prevents accidental or unauthorized controllin...

Страница 37: ...with the server is established If events registered by the alarm control panel are supposed to be sent by GSM LTE this option can be used to separate external line from the alarm control panel 7 7 1 3...

Страница 38: ...ooperation with a communicator it is possible to make a communicator to generate such tone 7 7 1 7 Detect off hook after The default value for the delay detection off hook is 100ms You can define your...

Страница 39: ...ContactID format Some control panel generate improper messages regarding a control sum for transmitted data the device is not able to confirm collection of data and as a result the panel tries to send...

Страница 40: ...on off hook dialing Communicator states Communication with the monitoring center information about update of time configuration changes start and finish of jamming etc Information information about t...

Страница 41: ...er using cellular data transmission This information is a valuable source of data about the operating conditions of the device such as Power supply voltage of the external control panel Mobile network...

Страница 42: ...channels click and select appropriate items Additional tabs will be displayed after selecting communication channels cellular network Ethernet SMS mode depends on what mode was selected 9 1 CELLULAR...

Страница 43: ...ers APN user ID and User Password must be completed see section 9 1 2 Servers 9 1 1 2 Profiles and profile settings This functionality allows you to define up to 3 mobile network operator profiles To...

Страница 44: ...option is selected additional parameters will be displayed and options for backup server settings and rules for cooperation with the main server Server Address It is the IP address of the monitoring s...

Страница 45: ...re for connecting with a backup server This option is enabled only when the secondary server has been defined Always try to connect to the primary server first Activating this option means that the de...

Страница 46: ...set not just a modem reset after detecting loss of network connection no transmission 9 2 SMS MODE The Text message mode may act as an autonomous data transmission channel as well as a backup channel...

Страница 47: ...etwork operator This code consists of up to 3 digits Below are several methods for determining the correct MCC and MNC codes Check via web browser Contact with the mobile network operator Best solutio...

Страница 48: ...s field empty or entering only one digit including 0 the device will never switch to Text message mode 9 2 3 Test event period Define here the period for sending the Test signal to inform the monitori...

Страница 49: ...Provide right PIN code for SIM card d Save settings into memory of device Saving course is displayed in special window e After saving disconnect power supply and disassembly service wire f Insert SIM...

Страница 50: ...dow g After saving completion close configuration wizard h The device is ready to transmit data 10 1 2 Reprogramming of device As the device has defined access parameters in respect of GPRS network an...

Страница 51: ...ommand Issues AT command to GSM modem and sends response back Optional timeout parameter defines time for modem response Time determined in seconds and ranges from 1 30 seconds If timeout isn t specif...

Страница 52: ...s in minutes time between SMS test messages sending to the server RLIMIT Removes automatic temporary locks on all inputs DT YY MM DD hh mm ss Set time in the transmitter Time must be specified in a fo...

Страница 53: ...M LTE 12 2 GSM LTE RANGE Flickering of a green diode OK indicates GSM signal 1 8 flickers Device operation mode is signalled with a green diode on during 2 seconds once the range was detected If after...

Страница 54: ...SMS Transmission 12 4 RECEIVING OF DTMF DATA Diodes marked as DTMF and STATUS indicate actual condition during receiving data from a control pane LED Diode Signalling STATUS DTMF HandShake KissOff 6 d...

Страница 55: ...r follows during updating there is bootloader in device and another programming of device is possible Description LED Diodes OK green ERROR red No program in device 1 sec Software updating Received fi...

Страница 56: ...y constant flashing of a red diode ERROR and mostly it means communication problem with modem or SIM card Programming of device is possible with EBS Config configuration program described in chapter 6...

Страница 57: ...ansmitter Configurator 31 10 2017 i1 7 Updated requirements for the computer installing the GPRS Transmitter Configurator replacement of OSM 2007 with OSM Server 09 08 2018 i1 8 Updated information in...

Отзывы: