PX200NB
–
Manual
Page 35 / 57
7.6.
RS232
In order to provide additional capabilities for sending information, LX30B-QxT
communicator is equipped with serial port RS-232, 3.3V TTL level. To connect
devices equipped with a standard RS-232 or RS-485 the appropriate cables and
converters are needed.
7.6.1.
Serial port settings
The selected parameters shall correspond to RS-232 port settings in device which
will be connected to the communicator. Available parameters are shown in the table
below:
Parameter
Value
Baud rate (bits/sec)
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Data bits
8
Parity
None, Even, Odd, Mark, Space
Stop bits
1, 2
Flow control
None, RTS, CTS, RTS/CTS
If RS232 checkbox will not be enabled, data to the Event monitor will be sent
on device’s serial port. With this setting, GD
-PROG cable can be used to
observe device state using EBS Config 2.0