PX200NB
–
Manual
Page 10 / 57
IN1
–
IN8
Signal inputs. Possible connection of detectors contacts or
alarm control panel outputs. GND terminal is common for
all inputs.
TMP
Input. Connection of monitoring sabotage switch (the
second switch contact connected to GND terminal)
NC, NO, C
Additional output indication relay. It may control external
device. During activation disconnects C terminal from NC,
and connects C to NO terminal.
+12V
Supply voltage output. Provides up to 200mA.
OUT1
Type OC sabotage output. It may control external device.
Provides ground during activation.
R1, T1
Connection to alarm control panel phone communicator
RING, TIP
Terminals for a PSTN telephone
PGND
Ground line for protecting an external phone line
NOTES:
OUT1 output can sink up to 10
0mA. Don’t short this output to power supply
because it can cause permanent damage of output.
Don’t connect power supply when GSM antenna isn’t connected, because it
can cause permanent damage of GSM/GPRS modem.
After careful connections examination a battery may be connected (to +ACU and GND
terminals) and then power may be switched on for transformer and programming
procedure of communicator may begin (See chapter 6. Configuration program).