3.2.
INPUT CONFIGURATION
Inputs IN1
–
IN8, TMP might work as normally closed (NC) or normally open (NO).
Additionally inputs might be configured as single end-of-line (EOL-NO or EOL-NC) with
resistors 2.
2kΩ or as double end
-of-line (DEOL-NO or DEOL-NC) with resistor 1.
1kΩ.
Examples of connecting sensors to the inputs in various configurations are shown in
figure 2.
Fig. 2. Examples of connecting sensors to the inputs in various configurations
3.3.
REMOTE CONTROL CONFIGURATION (ONLY PX200NB-5R
VERSION)
The device in version PX200NB-5R provides 2 additional virtual inputs that can be
triggered by radio communicators. The way of functioning should be configured by
GPRS configurator software.
Remote control programming procedure
Press PROG (B) and hold. After a moment, the red LED STATUS flash. If the button is
held longer, the red LED STATUS will flash second time and a third and then stop
blinking which would mean the exit from the programming process.
If the button will be released:
•
After the first STATUS LED flash, the communicator will enter the programming
mode the channel is responsible for virtual input #9. Status LED on. Pressing the