47
Phone:(910) 392
‐
2490
Fax: (910) 392
‐
2123
416 Landmark Drive
Wilmington, NC 28412
www.easterninstruments.com
You should now see the ADV.FILL page (right).
Press the ENABLE Bu on in order to toggle the
Fill Mode on and o
ff
. Press the CALCULATE TAR
‐
GET Bu on in order to enter your
fi
lling parame
‐
ters.
*Please note that
fi
lling using an Auxiliary
Feeder only u lizes the Manual Target Weight
Correc on method. The Auto Target is a pre
‐
dic ve method of determining the Weight Cor
‐
rec on that is only used in conjunc on with
the CentriFeeder with ICV.
Bag Fill Target
Press the Manual Target Bu on. You should now
see the ADV.FILL.MAN screen (right). Enter your
target
fi
ll weight under Bag Fill Target by clicking
on the 0.00 area. A numeric keypad will pop up
where you can enter your weight.
Weight Correc on
There are several ways to determine your Weight
Correc on. You can enter the weight correc on
if you already know the value (from previous
runs), you can determine the value by com
‐
ple ng a single run and entering the overshoot
(weight over the Bag Fill Target), or you can run
several runs in Learn Mode (explained in the Screen Guide).
The preferred method would be to leave your Weight Correc on at 0.00 lb and return to the
fi
lling screen or RUN.FILL page. Now run a single run and see once the feeder device has been
shut o
ff
, how much overshoot has occurred Please ensure that your Learn Mode is turned o
ff
.
The overshoot that you see can be entered as the Weight Correc on. Enter this value in the
Weight Correc on
fi
eld, just as you entered the Bag Fill Target. Example: If
you have a Bag Fill
Target of 25 lb and your
fi
rst run is 26.5 lb, then the Weight Correc
Ɵ
on in this case would be
1.5 lb. Using this value as a star
Ɵ
ng point, re
fi
ne the
Weight Correc on value by turning your
Learn Mode to slow and complete several more runs un l the Measured Target and the Bag
Fill Target are within acceptable tolerances. Learn Mode should be le on slow.