AUTOMATIC
Automa c Mode is a mode that enables the valve’s posi on, or output, to be changed auto
‐
ma cally based on a desired process Set Point. The valve will automa cally adjust un l the
Set Point is reached or maintained.
Entering Automa c Mode
You can access Automa c Mode from the Run page (pressing Run from the TOP page
‐
Main
Menu) by pressing the Automa c Bu on. You should now be in Automa c Mode. If you have
not run the CentriFeeder™ before, then simply press the Run/Stop Bu on and when it has
turned to green, the Integrated Control Valve will open.
If product has been run through the CentriFeeder™ before, then the stored Auto Delay value
should be indicated in the Control Out Display. Pressing the Run/Stop Bu on will signal to the
Integrated Control Valve to access the previously saved Auto Output value and will run in
Manual Mode for the allo ed me indicated in your Auto Delay Se ngs. A er the Auto Delay
set me has expired, the system will switch to Automa c Mode and you should see the Manu
‐
al Bu on change from green to gray and the Automa c Bu on change from gray to green indi
‐
ca ng that it has changed modes.
Changing the Set Point Value
The Process Set Point is similar to the Manual Output value for Manual Mode, however rather
than indica ng a percent open value for the valve itself, the Process Set Point indicates a per
‐
centage of your Electronic Full Scale value. This value can be changed by pressing on the Pro
‐
cess Set Point Bu on and entering your value in the pop up numeric keypad.
MANUAL
BUTTON
AUTO DELAY
INDICATOR
PROCESS SET
POINT BUTTON
AUTOMATIC
BUTTON