Parameters Setup Procedure - FLTR. PR & QUIT
FLTR. PR. menu is designed to allow user to specifies the filtering range of vibration for the vibration filtering
function.
This version of software is offering vibration filtering as one of the standard function in the ES-12.
This function is used prmary for big or very old machine which the machine structure is not ver y rigid to
resist the vibration when during machining or axis movement.
The bigger the FLTR. PR, the bigger the filtering effect. Slower movement will be observed.
Please notice that the vibration filter won't affect the accuracy of the counting. The measurement accuracy
is the same with or without the filter.
DRO displays "FLTR PR." means
DRO have entered into the
FLTR. PR selection menu, user
must specify the vibration
filtering range to the DRO.
specify the FLTR. PR
selection done,
go to next menu
For example, we change
the FLTR. PR to 60 for
higher filtering effect
6
0
Press to select the "FLTR. PR" selection menu
Press to select the "QUIT" selection menu
Please notice that the DRO must be switched
off after quit from the SETUP function, otherwise,
some of the new parameters may not be able
to take effect
- B. 23 -
X
Y
Z
U
FLTR. PR
X
Y
Z
U
FLTR. PR
30
X
Y
Z
U
FLTR. PR
60
X
Y
Z
U
QUIT.
X
Y
Z
U
FLTR. PR
30
Содержание ES-12
Страница 1: ...Always Committed to Quality Technology Innovation ES 12 Digital Readout System Operation Manual...
Страница 8: ...1 Basic Fucntions Basic Functions BASIC...
Страница 15: ...8 Built in Calculator Calculator...
Страница 27: ...20 REF datum memory...
Страница 31: ...24 LHOLE tool positioning for the Line Holes...
Страница 35: ...28 INCL Inclined angle tool positioning...
Страница 40: ...33 PCD tool positioning for Pitch Circle Diameter...
Страница 45: ...R R R 38 tool positioning for ARC machining...
Страница 63: ...R R R 56 Simplified R function...
Страница 73: ...66 Shrinkage Calculation L L X 1 005...
Страница 91: ...Parameter Setup B 1 SET UP...